Product
Lightning countermeasures SmartSPD for communication SMH-CLP seriesHandling Company
Sankosha Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | AC durability (measurement conditions: performance: measurement location) | Impulse durability (measurement conditions: performance: measurement location) | Impulse reset (measurement conditions: performance: measurement location) | Insertion loss (measurement conditions: performance: measurement location) | Insulation resistance (measurement conditions: performance: measurement location) | Main uses | Mass | Maximum continuous working voltage UC | Overload failure mode | Rated current | Series resistance (measurement conditions: performance: measurement location) | Voltage protection level UP (measurement conditions: performance: measurement location) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SMH-CLP-H3 6V |
Available upon quote | 50Hz, 0.5A, 1s: 5 times: between ground |
・8/20μs, 10kA: 10 times (Category C2): Between ground ・10/350μs, 2.5kA: 2 times (Category D1): Between ground |
DC48V, 260mA: 30ms or less: Between ground | DC~500kHz: 1.0dB or less: Between input and output | DC6V: 1MΩ or more: between lines | Transmission/instrumentation line | Approximately 120g | DC9V | Mode 1 | DC100mA | Per wire: 5Ω±10%: Between input and output (1 wire) | 1.2/50μs, 10kV: 80V or less: Between ground | |
SMH-CLP-H3 12V |
Available upon quote | 50Hz, 0.5A, 1s: 5 times: between ground |
・8/20μs, 10kA: 10 times (Category C2): Between ground ・10/350μs, 2.5kA: 2 times (Category D1): Between ground |
DC48V, 260mA: 30ms or less: Between ground | DC~1MHz: 1.0dB or less: Between input and output | DC13.5V: 1MΩ or more: between lines | Transmission/instrumentation line | Approximately 120g | DC13.5V | Mode 1 | DC100mA | Per wire: 5Ω±10%: Between input and output (1 wire) | 1.2/50μs, 10kV: 100V or less: Between ground | |
SMH-CLP-H3 24V |
Available upon quote | 50Hz, 0.5A, 1s: 5 times: between ground |
・8/20μs, 10kA: 10 times (Category C2): Between ground ・10/350μs, 2.5kA: 2 times (Category D1): Between ground |
DC48V, 260mA: 30ms or less: Between ground | DC~1MHz: 1.0dB or less: Between input and output | DC27V: 1MΩ or more: between lines | Transmission/instrumentation line | Approximately 120g | DC27V | Mode 1 | DC100mA | Per wire: 5Ω±10%: Between input and output (1 wire) | 1.2/50μs, 10kV: 120V or less: Between ground | |
SMH-CLP-H3 48V |
Available upon quote | 50Hz, 0.5A, 1s: 5 times: between ground |
・8/20μs, 10kA: 10 times (Category C2): Between ground ・10/350μs, 2.5kA: 2 times (Category D1): Between ground |
DC48V, 260mA: 30ms or less: Between ground | DC~1MHz: 1.0dB or less: Between input and output | DC52V: 1MΩ or more: between lines | Transmission/instrumentation line | Approximately 120g | DC52V | Mode 1 | DC100mA | Per wire: 5Ω±10%: Between input and output (1 wire) | 1.2/50μs, 10kV: 140V or less: Between ground | |
SMH-CLP-N1 |
Available upon quote | 50Hz, 0.5A, 1s: 5 times: between ground |
・8/20μs, 10kA: 10 times (Category C2): Between ground ・10/350μs, 1kA: 2 times (Category D1): Between ground |
DC48V, 260mA: 30ms or less: Between ground | DC~5MHz: 1.0dB or less: Between input and output | DC52V: 1MΩ or more: between lines | Transmission/instrumentation line | Approximately 120g | DC52V | Mode 1 | DC3A | 100mΩ or less: Between input and output (1 wire) | 1.2/50μs, 10kV: 500V or less: Between ground | |
SMH-CLP-NM |
Available upon quote | 50Hz, 0.5A, 1s: 5 times: between ground |
・8/20μs, 10kA: 10 times (Category C2): Between ground ・10/350μs, 1kA: 2 times (Category D1): Between ground |
DC48V, 260mA: 30ms or less: Between ground | DC~5MHz: 1.0dB or less: Between input and output | DC52V: 1MΩ or more: between lines | Transmission/instrumentation line | Approximately 120g | DC52V | Mode 1 | Because it is a bus wiring method, it does not affect the line current. | - | 1.2/50μs, 10kV: 500V or less: Between ground | |
SMH-CLP-K2 |
Available upon quote | 50Hz, 0.5A, 1s: 5 times: between ground |
・8/20μs, 10kA: 10 times (Category C2): Between ground ・10/350μs, 1kA: 2 times (Category D1): Between ground |
- | DC~10MHz: 1.0dB or less: Between input and output | DC180V: 100MΩ or more: between lines | Control line | Approximately 120g | DC180V, AC140V | Mode 1 | DC3A | Contact resistance 100mΩ or less: between input and output (1 wire) | 1.2/50μs, 10kV: 800V or less: Between ground | |
SMH-CLP-EN |
Available upon quote | 50Hz, 0.5A, 1s: 5 times: between ground |
・8/20μs, 10kA: 10 times (Category C2): Between ground ・10/350μs, 2.5kA: 2 times (Category D1): Between ground |
DC48V, 260mA: 30ms or less: Between ground | DC~10MHz: 1.0dB or less: Between input and output | DC180V: 1MΩ or more: between lines | Telephone line | Approximately 120g | DC180V | Mode 1 | DC100mA | Contact resistance per wire: 12Ω or less: Between input and output (1 wire) | 1.2/50μs, 10kV: 400V or less: Between ground | |
SMH-CLP-DC |
Available upon quote | 50Hz, 0.5A, 1s: 5 times: between ground |
・8/20μs, 10kA: 10 times (Category C2): Between ground ・10/350μs, 1.8kA: 2 times (Category D1): Between ground |
- | DC~500kHz: 1.0dB or less: Between input and output | - | DC power supply | Approximately 120g | DC52V | Mode 1 | DC3A | Contact resistance 100mΩ or less: between input and output (1 wire) | 1.2/50μs, 10kV: 500V or less: Between ground |
Click on the part number for more information about each product