Product Image | Part Number | Price (excluding tax) | Accuracy ORP | Accuracy pH | Accuracy temperature | Analog output 1 | Analog output 2 | Calibration mode | Cleaning contacts | Cleaning operation | Display | Environmental temperature | External dimensions | Input impedance | Installation | Logging | Measurement items | Measuring range ORP | Measuring range pH | Measuring range temperature | Model | Output voltage for external control | Panel cut dimensions | Power supply | Repeatability | Resolution ORP | Resolution pH | Resolution temperature | Serial interface | Setting contact | Setting operation | Temperature compensation |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PC-3110 |
Available upon quote | ±0.1% (±1Digit) | ±0.01pH (±1Digit) | ±0.2℃ (±1Digit) | Isolated type 0/4~20mA output compatible with pH/ORP maximum load resistance 500Ω | Isolated 0/4~20mA output corresponding to temperature | Any, Tech & NIST, 3-point calibration | 240V0.5A (maximum non-inductive load) A contact | ON: 0~99 minutes 59 seconds, OFF: 0~999 hours 59 minutes |
Large LCD display with auto-sensing backlight and contrast function text mode |
0~50℃ | 96×96×132mm (H×W×D), 1/4DIN | ≧1012Ω | Wall mounting, pipe mounting, panel mounting | - | PH/ORP/temperature | -1,999~1,999mV | -2.00~16.00pH | -30.0~130.0℃ | Standard model | DC±12V, max. 1W | 93×93mm (H×W) | 100~240VAC±10%50/60Hz max.9W | ±0.05pH | 1mV | 0.01pH | 0.1℃ | - | Max 240VAC0.5A | Hi/Lo, Hi/Hi, Lo/Lo and ON/OFF selection | 25℃ automatic temperature compensation/manual setting for NTC30K or Pt1000 | |
PC-3110RS |
Available upon quote | ±0.1% (±1Digit) | ±0.01pH (±1Digit) | ±0.2℃ (±1Digit) | Isolated type 0/4~20mA output compatible with pH/ORP maximum load resistance 500Ω | - | Any, Tech & NIST, custom setting 5-point calibration | 240V0.5A (maximum non-inductive load) A contact | ON: 0~99 minutes 59 seconds, OFF: 0~999 hours 59 minutes |
Large LCD display with auto-sensing backlight and contrast function Text and chart/trace mode |
0~50℃ | 96×96×132mm (H×W×D), 1/4DIN | ≧1012Ω | Wall mounting, pipe mounting, panel mounting | 50 records | PH/ORP/temperature | -1,999~1,999mV | -2.00~16.00pH | -30.0~130.0℃ | Model with digital communication function | DC±12V, max. 1W | 93×93mm (H×W) | 100~240VAC±10%50/60Hz max.9W | ±0.05pH | 1mV | 0.01pH | 0.1℃ | RS-485 (ModbusRTU or ASCII) | Max 240VAC0.5A | Hi/Lo, Hi/Hi, Lo/Lo and ON/OFF selection | 25℃ automatic temperature compensation/manual setting for NTC30K or Pt1000 |