Product
Sensor series with built-in transmitter Polylite Plus H Arc pH measurement sensorHandling Company
T&C Technical Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | 4-20mA output 1 | Analog interface operating temperature range | Autoclave | CIP | Diaphragm | Digital interface | Digital interface operating temperature range | Electrical connection | Electrolyte | Internal electrolyte gland | Measuring range | Membrane glass | Mounting format | Number of diaphragms | O-ring | Operating power supply voltage | PH measurement temperature range | Power consumption | Process conductivity | Process pressure | Proof | Reference electrode system | SIP | Sensitivity | Sensor length | Shaft diameter | Shaft material | Storage | Unit of measurement | Zero point |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
242428-1313 |
Available upon quote |
PH measurement value Any range can be set using a PC. |
0~+110℃ | Correspondence |
H glass: Not possible HB glass: Possible *P/N will change for HB glass model |
Single pore |
ModbusRTU protocol 2-wire RS-485; max. 31 addresses Communication speed/baud rate: 4800 to 115000bps (factory setting: 19,200bps) |
0~+130℃ | VP8.0 socket head | Polysolve plus | None | 0~14pH Resolution: 0.01pH | Hamilton h glass | PG13.5 | 2 | FKM | 7~30VDC | 0℃~+130℃ | Max 150mW | 2μS/cm or more |
Below 100℃: 0~1.6MPa Below 130℃: 0~1.0MPa |
Material certification, CE mark | Hamilton Everref L | Correspondence | 57mV~59mV/pH | 120mm | 12mm | Glass |
Hamilton storage electrolyte Or 3mol KCl solution |
PH: pH, mV Temperature: ℃, K | ±20mV@25℃ | |
242428-1323 |
Available upon quote |
PH measurement value Any range can be set using a PC. |
0~+110℃ | Correspondence |
H glass: Not possible HB glass: Possible *P/N will change for HB glass model |
Single pore |
ModbusRTU protocol 2-wire RS-485; max. 31 addresses Communication speed/baud rate: 4800 to 115000bps (factory setting: 19,200bps) |
0~+130℃ | VP8.0 socket head | Polysolve plus | None | 0~14pH Resolution: 0.01pH | Hamilton h glass | PG13.5 | 2 | FKM | 7~30VDC | 0℃~+130℃ | Max 150mW | 2μS/cm or more |
Below 100℃: 0~1.6MPa Below 130℃: 0~1.0MPa |
Material certification, CE mark | Hamilton Everref L | Correspondence | 57mV~59mV/pH | 225mm | 12mm | Glass |
Hamilton storage electrolyte Or 3mol KCl solution |
PH: pH, mV Temperature: ℃, K | ±20mV@25℃ | |
242428-1333 |
Available upon quote |
PH measurement value Any range can be set using a PC. |
0~+110℃ | Correspondence |
H glass: Not possible HB glass: Possible *P/N will change for HB glass model |
Single pore |
ModbusRTU protocol 2-wire RS-485; max. 31 addresses Communication speed/baud rate: 4800 to 115000bps (factory setting: 19,200bps) |
0~+130℃ | VP8.0 socket head | Polysolve plus | None | 0~14pH Resolution: 0.01pH | Hamilton h glass | PG13.5 | 2 | FKM | 7~30VDC | 0℃~+130℃ | Max 150mW | 2μS/cm or more |
Below 100℃: 0~1.6MPa Below 130℃: 0~1.0MPa |
Material certification, CE mark | Hamilton Everref L | Correspondence | 57mV~59mV/pH | 325mm | 12mm | Glass |
Hamilton storage electrolyte Or 3mol KCl solution |
PH: pH, mV Temperature: ℃, K | ±20mV@25℃ | |
242428-1353 |
Available upon quote |
PH measurement value Any range can be set using a PC. |
0~+110℃ | Correspondence |
H glass: Not possible HB glass: Possible *P/N will change for HB glass model |
Single pore |
ModbusRTU protocol 2-wire RS-485; max. 31 addresses Communication speed/baud rate: 4800 to 115000bps (factory setting: 19,200bps) |
0~+130℃ | VP8.0 socket head | Polysolve plus | None | 0~14pH Resolution: 0.01pH | Hamilton h glass | PG13.5 | 2 | FKM | 7~30VDC | 0℃~+130℃ | Max 150mW | 2μS/cm or more |
Below 100℃: 0~1.6MPa Below 130℃: 0~1.0MPa |
Material certification, CE mark | Hamilton Everref L | Correspondence | 57mV~59mV/pH | 425mm | 12mm | Glass |
Hamilton storage electrolyte Or 3mol KCl solution |
PH: pH, mV Temperature: ℃, K | ±20mV@25℃ |
Click on the part number for more information about each product