Product
Sensor series with built-in transmitter Easy Farm Bio HB Arc pH measurement sensorHandling Company
T&C Technical Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | 4-20mA output | Analog interface operating temperature range | Autoclave | CIP | Diaphragm | Digital interface | Digital interface operating temperature range | Electrical connection | Electrolyte | Internal electrolyte gland | Measuring range | Membrane glass | Mounting format | Number of diaphragms | O-ring | Operating power supply voltage | PH measurement temperature range | Power consumption | Process conductivity | Process pressure | Proof | Reference electrode system | SIP | Sensitivity | Sensor length | Shaft diameter | Shaft material | Storage | Unit of measurement | Zero point |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
243632-2313 |
Available upon quote |
PH measurement value Any range can be set using a PC. |
0~+110℃ | Compatible (up to 130℃) | Correspondence | HP Coat Ramic |
ModbusRTU protocol 2-wire RS-485; max. 31 addresses Communication speed/baud rate: 4,800 to 115,000bps (factory setting: 19,200bps) |
0~+140℃ | VP8.0 socket head | Pressurized hood light | Yes | 0~14pH Resolution: 0.01pH | Hamilton hb glass | PG13.5 | 1 | VMQ (silicone elastomer) | 7~30VDC | 0℃~+140℃ | Max 150mW | 100μS/cm or more | 0~0.6MPa | Material certification, EHEDG and biocompatibility (MDT) tested, CE marked | Hamilton Everref F with silver ion barrier | Compatible (up to 140℃) | 57mV~59mV/pH | 120mm | 12mm | Glass | Hamilton storage electrolyte or 3mol KCl solution | PH: pH, mV Temperature: ℃, K | ±20mV@25℃ | |
243632-2323 |
Available upon quote |
PH measurement value Any range can be set using a PC. |
0~+110℃ | Compatible (up to 130℃) | Correspondence | HP Coat Ramic |
ModbusRTU protocol 2-wire RS-485; max. 31 addresses Communication speed/baud rate: 4,800 to 115,000bps (factory setting: 19,200bps) |
0~+140℃ | VP8.0 socket head | Pressurized hood light | Yes | 0~14pH Resolution: 0.01pH | Hamilton hb glass | PG13.5 | 1 | VMQ (silicone elastomer) | 7~30VDC | 0℃~+140℃ | Max 150mW | 100μS/cm or more | 0~0.6MPa | Material certification, EHEDG and biocompatibility (MDT) tested, CE marked | Hamilton Everref F with silver ion barrier | Compatible (up to 140℃) | 57mV~59mV/pH | 160mm | 12mm | Glass | Hamilton storage electrolyte or 3mol KCl solution | PH: pH, mV Temperature: ℃, K | ±20mV@25℃ | |
243632-2333 |
Available upon quote |
PH measurement value Any range can be set using a PC. |
0~+110℃ | Compatible (up to 130℃) | Correspondence | HP Coat Ramic |
ModbusRTU protocol 2-wire RS-485; max. 31 addresses Communication speed/baud rate: 4,800 to 115,000bps (factory setting: 19,200bps) |
0~+140℃ | VP8.0 socket head | Pressurized hood light | Yes | 0~14pH Resolution: 0.01pH | Hamilton hb glass | PG13.5 | 1 | VMQ (silicone elastomer) | 7~30VDC | 0℃~+140℃ | Max 150mW | 100μS/cm or more | 0~0.6MPa | Material certification, EHEDG and biocompatibility (MDT) tested, CE marked | Hamilton Everref F with silver ion barrier | Compatible (up to 140℃) | 57mV~59mV/pH | 200mm | 12mm | Glass | Hamilton storage electrolyte or 3mol KCl solution | PH: pH, mV Temperature: ℃, K | ±20mV@25℃ | |
243632-2343 |
Available upon quote |
PH measurement value Any range can be set using a PC. |
0~+110℃ | Compatible (up to 130℃) | Correspondence | HP Coat Ramic |
ModbusRTU protocol 2-wire RS-485; max. 31 addresses Communication speed/baud rate: 4,800 to 115,000bps (factory setting: 19,200bps) |
0~+140℃ | VP8.0 socket head | Pressurized hood light | Yes | 0~14pH Resolution: 0.01pH | Hamilton hb glass | PG13.5 | 1 | VMQ (silicone elastomer) | 7~30VDC | 0℃~+140℃ | Max 150mW | 100μS/cm or more | 0~0.6MPa | Material certification, EHEDG and biocompatibility (MDT) tested, CE marked | Hamilton Everref F with silver ion barrier | Compatible (up to 140℃) | 57mV~59mV/pH | 225mm | 12mm | Glass | Hamilton storage electrolyte or 3mol KCl solution | PH: pH, mV Temperature: ℃, K | ±20mV@25℃ | |
243632-2353 |
Available upon quote |
PH measurement value Any range can be set using a PC. |
0~+110℃ | Compatible (up to 130℃) | Correspondence | HP Coat Ramic |
ModbusRTU protocol 2-wire RS-485; max. 31 addresses Communication speed/baud rate: 4,800 to 115,000bps (factory setting: 19,200bps) |
0~+140℃ | VP8.0 socket head | Pressurized hood light | Yes | 0~14pH Resolution: 0.01pH | Hamilton hb glass | PG13.5 | 1 | VMQ (silicone elastomer) | 7~30VDC | 0℃~+140℃ | Max 150mW | 100μS/cm or more | 0~0.6MPa | Material certification, EHEDG and biocompatibility (MDT) tested, CE marked | Hamilton Everref F with silver ion barrier | Compatible (up to 140℃) | 57mV~59mV/pH | 325mm | 12mm | Glass | Hamilton storage electrolyte or 3mol KCl solution | PH: pH, mV Temperature: ℃, K | ±20mV@25℃ | |
243632-2373 |
Available upon quote |
PH measurement value Any range can be set using a PC. |
0~+110℃ | Compatible (up to 130℃) | Correspondence | HP Coat Ramic |
ModbusRTU protocol 2-wire RS-485; max. 31 addresses Communication speed/baud rate: 4,800 to 115,000bps (factory setting: 19,200bps) |
0~+140℃ | VP8.0 socket head | Pressurized hood light | Yes | 0~14pH Resolution: 0.01pH | Hamilton hb glass | PG13.5 | 1 | VMQ (silicone elastomer) | 7~30VDC | 0℃~+140℃ | Max 150mW | 100μS/cm or more | 0~0.6MPa | Material certification, EHEDG and biocompatibility (MDT) tested, CE marked | Hamilton Everref F with silver ion barrier | Compatible (up to 140℃) | 57mV~59mV/pH | 425mm | 12mm | Glass | Hamilton storage electrolyte or 3mol KCl solution | PH: pH, mV Temperature: ℃, K | ±20mV@25℃ |
Click on the part number for more information about each product