Sensor series with built-in transmitter VisiFarm DO ECS optical dissolved oxygen measurement sensor-243666-211
Sensor series with built-in transmitter VisiFarm DO ECS optical dissolved oxygen measurement sensor-T&C Technical Co., Ltd.

Sensor series with built-in transmitter VisiFarm DO ECS optical dissolved oxygen measurement sensor
T&C Technical Co., Ltd.


About This Product

■Features Using LED light and a phosphor that absorbs and emits light, oxygen concentration is measured in the range of 4ppb to 25ppm using the principle that the light emitted by the phosphor is absorbed by oxygen. The phosphor uses a cap design. Replacement is easy and reliable. Calibration allows you to replace the cap at an appropriate time by monitoring the deterioration of the cap. The work will be completed in about 20 minutes. It does not have an electrolyte like traditional Clark cells. Measurement is not affected by flow rate or pressure. Therefore, there is no instability in measured values ​​due to stirring, and it is possible to measure the state of dissolved oxygen depending on the installation location, such as the bottom of a tank. Since there is no self-consumption of oxygen by the sensor, dissolved oxygen can be accurately measured at low concentrations or in stationary liquids. Sensor lengths can be selected from 120mm, 160mm, 215mm, 325mm, and 425mm. Two types of fluorescent films are available: silicon and Teflon. It can be selected according to the properties of the measuring liquid and the purpose.

  • Product

    Sensor series with built-in transmitter VisiFarm DO ECS optical dissolved oxygen measurement sensor

Share this product


380+ people viewing

Last viewed: 4 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Sensor series with built-in transmitter VisiFarm DO ECS optical dissolved oxygen measurement sensor

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Accuracy Analog output Cleaning sterilization performance Continuous power consumption DO measurement temperature range Digital interface Electrical connection Flow rate regulation Maintenance parts Measurement error Measurement limit value Measurement principle Measuring range Model Operating power supply voltage Operating temperature range Process pressure Response time Shaft length Shape and mounting shape Shipping condition Storage temperature Unit of measurement Wetted parts
Sensor series with built-in transmitter VisiFarm DO ECS optical dissolved oxygen measurement sensor-Part Number-243666-211

243666-211

Available upon quote 1±0.05%-vol, 21±0.2%-vol, 50±0.5%-vol (25℃) 4-20mA (measured value)
*Non-isolated, PWM 3.5kHz output
Any range can be set using a PC.
Compatible with CIP, SIP, and autoclave 0.6W Power consumption at startup: 1W -10℃~+85℃
If the temperature exceeds 85℃, it will be held at the previous value.
When the temperature returns to the DO measurement temperature range, DO measurement will automatically resume.
ModbusRTU protocol
2-wire RS-485
VP8.0 socket head None
Additionally, this sensor does not consume oxygen in principle.
Fluorescent membrane replacement cap 1%/week or less (at constant temperature) 0.01%-vol. Optical 4ppb~25ppm Resolution: 0.1ppb (0~62.85%-vol, 0~300%-sat) H0 model (made of silicone) 7~30VDC Max 1000mW -10℃~+140℃ -0.1~1.2MPa From atmosphere to anoxic state (25℃):
When the fluorescent film is silicon: 98% response within 30 seconds
If the fluorescent film is Teflon: 98% response within 60 seconds
120mm Shaft diameter 12mm, mounting screw PG13.5
Shaft length: 120mm, 160mm, 215mm, 325mm, 425mm
It has been proofread. Can be measured at the same time as installation -10℃~+50℃ % oxygen/air saturation concentration (%-sat.), % oxygen concentration by volume (%-vol.), mg/L (ppm), μg/L (ppb) SUS316L (DIN1.4435), EPDM (FDA), silicone or Teflon (FDA)
Sensor series with built-in transmitter VisiFarm DO ECS optical dissolved oxygen measurement sensor-Part Number-243666-221

243666-221

Available upon quote 1±0.05%-vol, 21±0.2%-vol, 50±0.5%-vol (25℃) 4-20mA (measured value)
*Non-isolated, PWM 3.5kHz output
Any range can be set using a PC.
Compatible with CIP, SIP, and autoclave 0.6W Power consumption at startup: 1W -10℃~+85℃
If the temperature exceeds 85℃, it will be held at the previous value.
When the temperature returns to the DO measurement temperature range, DO measurement will automatically resume.
ModbusRTU protocol
2-wire RS-485
VP8.0 socket head None
Additionally, this sensor does not consume oxygen in principle.
Fluorescent membrane replacement cap 1%/week or less (at constant temperature) 0.01%-vol. Optical 4ppb~25ppm Resolution: 0.1ppb (0~62.85%-vol, 0~300%-sat) H0 model (made of silicone) 7~30VDC Max 1000mW -10℃~+140℃ -0.1~1.2MPa From atmosphere to anoxic state (25℃):
When the fluorescent film is silicon: 98% response within 30 seconds
If the fluorescent film is Teflon: 98% response within 60 seconds
160mm Shaft diameter 12mm, mounting screw PG13.5
Shaft length: 120mm, 160mm, 215mm, 325mm, 425mm
It has been proofread. Can be measured at the same time as installation -10℃~+50℃ % oxygen/air saturation concentration (%-sat.), % oxygen concentration by volume (%-vol.), mg/L (ppm), μg/L (ppb) SUS316L (DIN1.4435), EPDM (FDA), silicone or Teflon (FDA)
Sensor series with built-in transmitter VisiFarm DO ECS optical dissolved oxygen measurement sensor-Part Number-243666-231

243666-231

Available upon quote 1±0.05%-vol, 21±0.2%-vol, 50±0.5%-vol (25℃) 4-20mA (measured value)
*Non-isolated, PWM 3.5kHz output
Any range can be set using a PC.
Compatible with CIP, SIP, and autoclave 0.6W Power consumption at startup: 1W -10℃~+85℃
If the temperature exceeds 85℃, it will be held at the previous value.
When the temperature returns to the DO measurement temperature range, DO measurement will automatically resume.
ModbusRTU protocol
2-wire RS-485
VP8.0 socket head None
Additionally, this sensor does not consume oxygen in principle.
Fluorescent membrane replacement cap 1%/week or less (at constant temperature) 0.01%-vol. Optical 4ppb~25ppm Resolution: 0.1ppb (0~62.85%-vol, 0~300%-sat) H0 model (made of silicone) 7~30VDC Max 1000mW -10℃~+140℃ -0.1~1.2MPa From atmosphere to anoxic state (25℃):
When the fluorescent film is silicon: 98% response within 30 seconds
If the fluorescent film is Teflon: 98% response within 60 seconds
215mm Shaft diameter 12mm, mounting screw PG13.5
Shaft length: 120mm, 160mm, 215mm, 325mm, 425mm
It has been proofread. Can be measured at the same time as installation -10℃~+50℃ % oxygen/air saturation concentration (%-sat.), % oxygen concentration by volume (%-vol.), mg/L (ppm), μg/L (ppb) SUS316L (DIN1.4435), EPDM (FDA), silicone or Teflon (FDA)
Sensor series with built-in transmitter VisiFarm DO ECS optical dissolved oxygen measurement sensor-Part Number-243666-241

243666-241

Available upon quote 1±0.05%-vol, 21±0.2%-vol, 50±0.5%-vol (25℃) 4-20mA (measured value)
*Non-isolated, PWM 3.5kHz output
Any range can be set using a PC.
Compatible with CIP, SIP, and autoclave 0.6W Power consumption at startup: 1W -10℃~+85℃
If the temperature exceeds 85℃, it will be held at the previous value.
When the temperature returns to the DO measurement temperature range, DO measurement will automatically resume.
ModbusRTU protocol
2-wire RS-485
VP8.0 socket head None
Additionally, this sensor does not consume oxygen in principle.
Fluorescent membrane replacement cap 1%/week or less (at constant temperature) 0.01%-vol. Optical 4ppb~25ppm Resolution: 0.1ppb (0~62.85%-vol, 0~300%-sat) H0 model (made of silicone) 7~30VDC Max 1000mW -10℃~+140℃ -0.1~1.2MPa From atmosphere to anoxic state (25℃):
When the fluorescent film is silicon: 98% response within 30 seconds
If the fluorescent film is Teflon: 98% response within 60 seconds
325mm Shaft diameter 12mm, mounting screw PG13.5
Shaft length: 120mm, 160mm, 215mm, 325mm, 425mm
It has been proofread. Can be measured at the same time as installation -10℃~+50℃ % oxygen/air saturation concentration (%-sat.), % oxygen concentration by volume (%-vol.), mg/L (ppm), μg/L (ppb) SUS316L (DIN1.4435), EPDM (FDA), silicone or Teflon (FDA)
Sensor series with built-in transmitter VisiFarm DO ECS optical dissolved oxygen measurement sensor-Part Number-243666-251

243666-251

Available upon quote 1±0.05%-vol, 21±0.2%-vol, 50±0.5%-vol (25℃) 4-20mA (measured value)
*Non-isolated, PWM 3.5kHz output
Any range can be set using a PC.
Compatible with CIP, SIP, and autoclave 0.6W Power consumption at startup: 1W -10℃~+85℃
If the temperature exceeds 85℃, it will be held at the previous value.
When the temperature returns to the DO measurement temperature range, DO measurement will automatically resume.
ModbusRTU protocol
2-wire RS-485
VP8.0 socket head None
Additionally, this sensor does not consume oxygen in principle.
Fluorescent membrane replacement cap 1%/week or less (at constant temperature) 0.01%-vol. Optical 4ppb~25ppm Resolution: 0.1ppb (0~62.85%-vol, 0~300%-sat) H0 model (made of silicone) 7~30VDC Max 1000mW -10℃~+140℃ -0.1~1.2MPa From atmosphere to anoxic state (25℃):
When the fluorescent film is silicon: 98% response within 30 seconds
If the fluorescent film is Teflon: 98% response within 60 seconds
425mm Shaft diameter 12mm, mounting screw PG13.5
Shaft length: 120mm, 160mm, 215mm, 325mm, 425mm
It has been proofread. Can be measured at the same time as installation -10℃~+50℃ % oxygen/air saturation concentration (%-sat.), % oxygen concentration by volume (%-vol.), mg/L (ppm), μg/L (ppb) SUS316L (DIN1.4435), EPDM (FDA), silicone or Teflon (FDA)
Sensor series with built-in transmitter VisiFarm DO ECS optical dissolved oxygen measurement sensor-Part Number-243666-212

243666-212

Available upon quote 1±0.05%-vol, 21±0.2%-vol, 50±0.5%-vol (25℃) 4-20mA (measured value)
*Non-isolated, PWM 3.5kHz output
Any range can be set using a PC.
Compatible with CIP, SIP, and autoclave 0.6W Power consumption at startup: 1W -10℃~+85℃
If the temperature exceeds 85℃, it will be held at the previous value.
When the temperature returns to the DO measurement temperature range, DO measurement will automatically resume.
ModbusRTU protocol
2-wire RS-485
VP8.0 socket head None
Additionally, this sensor does not consume oxygen in principle.
Fluorescent membrane replacement cap 1%/week or less (at constant temperature) 0.01%-vol. Optical 4ppb~25ppm Resolution: 0.1ppb (0~62.85%-vol, 0~300%-sat) H2 model (made of Teflon) 7~30VDC Max 1000mW -10℃~+140℃ -0.1~1.2MPa From atmosphere to anoxic state (25℃):
When the fluorescent film is silicon: 98% response within 30 seconds
If the fluorescent film is Teflon: 98% response within 60 seconds
120mm Shaft diameter 12mm, mounting screw PG13.5
Shaft length: 120mm, 160mm, 215mm, 325mm, 425mm
It has been proofread. Can be measured at the same time as installation -10℃~+50℃ % oxygen/air saturation concentration (%-sat.), % oxygen concentration by volume (%-vol.), mg/L (ppm), μg/L (ppb) SUS316L (DIN1.4435), EPDM (FDA), silicone or Teflon (FDA)
Sensor series with built-in transmitter VisiFarm DO ECS optical dissolved oxygen measurement sensor-Part Number-243666-222

243666-222

Available upon quote 1±0.05%-vol, 21±0.2%-vol, 50±0.5%-vol (25℃) 4-20mA (measured value)
*Non-isolated, PWM 3.5kHz output
Any range can be set using a PC.
Compatible with CIP, SIP, and autoclave 0.6W Power consumption at startup: 1W -10℃~+85℃
If the temperature exceeds 85℃, it will be held at the previous value.
When the temperature returns to the DO measurement temperature range, DO measurement will automatically resume.
ModbusRTU protocol
2-wire RS-485
VP8.0 socket head None
Additionally, this sensor does not consume oxygen in principle.
Fluorescent membrane replacement cap 1%/week or less (at constant temperature) 0.01%-vol. Optical 4ppb~25ppm Resolution: 0.1ppb (0~62.85%-vol, 0~300%-sat) H2 model (made of Teflon) 7~30VDC Max 1000mW -10℃~+140℃ -0.1~1.2MPa From atmosphere to anoxic state (25℃):
When the fluorescent film is silicon: 98% response within 30 seconds
If the fluorescent film is Teflon: 98% response within 60 seconds
160mm Shaft diameter 12mm, mounting screw PG13.5
Shaft length: 120mm, 160mm, 215mm, 325mm, 425mm
It has been proofread. Can be measured at the same time as installation -10℃~+50℃ % oxygen/air saturation concentration (%-sat.), % oxygen concentration by volume (%-vol.), mg/L (ppm), μg/L (ppb) SUS316L (DIN1.4435), EPDM (FDA), silicone or Teflon (FDA)
Sensor series with built-in transmitter VisiFarm DO ECS optical dissolved oxygen measurement sensor-Part Number-243666-232

243666-232

Available upon quote 1±0.05%-vol, 21±0.2%-vol, 50±0.5%-vol (25℃) 4-20mA (measured value)
*Non-isolated, PWM 3.5kHz output
Any range can be set using a PC.
Compatible with CIP, SIP, and autoclave 0.6W Power consumption at startup: 1W -10℃~+85℃
If the temperature exceeds 85℃, it will be held at the previous value.
When the temperature returns to the DO measurement temperature range, DO measurement will automatically resume.
ModbusRTU protocol
2-wire RS-485
VP8.0 socket head None
Additionally, this sensor does not consume oxygen in principle.
Fluorescent membrane replacement cap 1%/week or less (at constant temperature) 0.01%-vol. Optical 4ppb~25ppm Resolution: 0.1ppb (0~62.85%-vol, 0~300%-sat) H2 model (made of Teflon) 7~30VDC Max 1000mW -10℃~+140℃ -0.1~1.2MPa From atmosphere to anoxic state (25℃):
When the fluorescent film is silicon: 98% response within 30 seconds
If the fluorescent film is Teflon: 98% response within 60 seconds
215mm Shaft diameter 12mm, mounting screw PG13.5
Shaft length: 120mm, 160mm, 215mm, 325mm, 425mm
It has been proofread. Can be measured at the same time as installation -10℃~+50℃ % oxygen/air saturation concentration (%-sat.), % oxygen concentration by volume (%-vol.), mg/L (ppm), μg/L (ppb) SUS316L (DIN1.4435), EPDM (FDA), silicone or Teflon (FDA)
Sensor series with built-in transmitter VisiFarm DO ECS optical dissolved oxygen measurement sensor-Part Number-243666-242

243666-242

Available upon quote 1±0.05%-vol, 21±0.2%-vol, 50±0.5%-vol (25℃) 4-20mA (measured value)
*Non-isolated, PWM 3.5kHz output
Any range can be set using a PC.
Compatible with CIP, SIP, and autoclave 0.6W Power consumption at startup: 1W -10℃~+85℃
If the temperature exceeds 85℃, it will be held at the previous value.
When the temperature returns to the DO measurement temperature range, DO measurement will automatically resume.
ModbusRTU protocol
2-wire RS-485
VP8.0 socket head None
Additionally, this sensor does not consume oxygen in principle.
Fluorescent membrane replacement cap 1%/week or less (at constant temperature) 0.01%-vol. Optical 4ppb~25ppm Resolution: 0.1ppb (0~62.85%-vol, 0~300%-sat) H2 model (made of Teflon) 7~30VDC Max 1000mW -10℃~+140℃ -0.1~1.2MPa From atmosphere to anoxic state (25℃):
When the fluorescent film is silicon: 98% response within 30 seconds
If the fluorescent film is Teflon: 98% response within 60 seconds
325mm Shaft diameter 12mm, mounting screw PG13.5
Shaft length: 120mm, 160mm, 215mm, 325mm, 425mm
It has been proofread. Can be measured at the same time as installation -10℃~+50℃ % oxygen/air saturation concentration (%-sat.), % oxygen concentration by volume (%-vol.), mg/L (ppm), μg/L (ppb) SUS316L (DIN1.4435), EPDM (FDA), silicone or Teflon (FDA)
Sensor series with built-in transmitter VisiFarm DO ECS optical dissolved oxygen measurement sensor-Part Number-243666-252

243666-252

Available upon quote 1±0.05%-vol, 21±0.2%-vol, 50±0.5%-vol (25℃) 4-20mA (measured value)
*Non-isolated, PWM 3.5kHz output
Any range can be set using a PC.
Compatible with CIP, SIP, and autoclave 0.6W Power consumption at startup: 1W -10℃~+85℃
If the temperature exceeds 85℃, it will be held at the previous value.
When the temperature returns to the DO measurement temperature range, DO measurement will automatically resume.
ModbusRTU protocol
2-wire RS-485
VP8.0 socket head None
Additionally, this sensor does not consume oxygen in principle.
Fluorescent membrane replacement cap 1%/week or less (at constant temperature) 0.01%-vol. Optical 4ppb~25ppm Resolution: 0.1ppb (0~62.85%-vol, 0~300%-sat) H2 model (made of Teflon) 7~30VDC Max 1000mW -10℃~+140℃ -0.1~1.2MPa From atmosphere to anoxic state (25℃):
When the fluorescent film is silicon: 98% response within 30 seconds
If the fluorescent film is Teflon: 98% response within 60 seconds
425mm Shaft diameter 12mm, mounting screw PG13.5
Shaft length: 120mm, 160mm, 215mm, 325mm, 425mm
It has been proofread. Can be measured at the same time as installation -10℃~+50℃ % oxygen/air saturation concentration (%-sat.), % oxygen concentration by volume (%-vol.), mg/L (ppm), μg/L (ppb) SUS316L (DIN1.4435), EPDM (FDA), silicone or Teflon (FDA)

Click on the part number for more information about each product