Multi-microplate reader SH-9500 series-SH-9500Lab A Absorption measurement
Multi-microplate reader SH-9500 series-SH-9500Lab F Fluorescence measurement
Multi-microplate reader SH-9500 series-SH-9500Lab BF downward fluorescence measurement
Multi-microplate reader SH-9500 series-SH-9500Lab T Time-resolved fluorescence measurement
Multi-microplate reader SH-9500 series-SH-9500Lab C Luminescence measurement
Multi-microplate reader SH-9500 series-SH-9500N(BG) A Absorption measurement
Multi-microplate reader SH-9500 series-SH-9500N(BG) F Fluorescence measurement
Multi-microplate reader SH-9500 series-Corona Electric Co., Ltd.

Multi-microplate reader SH-9500 series
Corona Electric Co., Ltd.


About This Product

To meet diverse research needs. Introducing an advanced grating-type multi-microplate reader. It can be used in a wide range of fields including life science, food, cosmetics, and pharmaceuticals. ■5 measurement modes Absorption, upward fluorescence, downward fluorescence, time-resolved fluorescence, and luminescence functions can be freely combined according to your budget and purpose. ■Various optional functions Constant temperature function, dispensing function, 10 mm cell function (absorption/fluorescence) ■Module options can be added After purchasing the device, you can add functions as needed. (Downward fluorescence cannot be added to a device equipped with upward fluorescence) ■Fluorescence sensitivity significantly increased Fluorescence measurements that require higher sensitivity are now possible. ■Measurement speed increased This increases measurement speed and reduces work time. ■Three reliable supports - Even if the device breaks down, we will provide free support for 3 years (excluding light source lamp/dispensing function). - Equipped with automatic log and backup functions. All operations are automatically recorded (log function), and even if important data is accidentally deleted, it can be restored using the automatic backup function. - Automatically diagnoses the optical system and drive unit at startup. ■Software SF7 that has evolved to be even easier to use Can be operated on a tablet device. Stress-free with simple operability. SF7 has a completely redesigned operation screen. Large icons have been arranged, and items have been simplified and optimized for tablet devices. You can quickly switch what you want to measure using tabs and save protocols to make daily operations stress-free.You can also set coloring rules for measured values, and view graphs and heat maps at a glance. ■Features ・Language switching between Japanese and English is possible ・User switching function: Protocols etc. can be managed for each user. This is a convenient function when used by multiple users. ・Data conversion to Excel and CSV: Measurement results can be automatically converted to a format suitable for the purpose. -Various analysis tools: This software allows analysis such as 6 types of calibration curve calculations, 5 types of kinetic calculations, spectral analysis, and cutoff calculations.

  • Product

    Multi-microplate reader SH-9500 series

Share this product


580+ people viewing

Last viewed: 20 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

8 Models of Multi-microplate reader SH-9500 series

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Compatible plate Detector External dimensions External terminal Focus Half width (irradiation spot diameter) Light source Linearity Main accessories Mass Measurement interval, number of times Measurement method Measurement sensitivity (96 wells) Measurement time Measuring direction Measuring range Others Photometry Plate color/bottom shape Power consumption Reproducibility Spectroscopic method Stirring function Wavelength range Wavelength resolution
Multi-microplate reader SH-9500 series-Part Number-SH-9500Lab A Absorption measurement

SH-9500Lab A Absorption measurement

Available upon quote 6, 12, 24, 48, 96, 384 well plates (more than 300 types registered), custom plate compatible (height 23 mm or less) Silicon photodiode 450 (W) × 500 (D) × 379 (H) mm USB x 1, RS-232C x 1 (both for PC connection) Variable 2.5, 5, 10 nm (about φ1.6mm) Xenon flash lamp ±0.5 T or ±0.005 Abs (0 ~ 2.5 Abs) Power cable, fuse, USB cable, tools, instruction manual, simple manual, software CD (SF7) Up to 42 kg (depending on combination of measuring functions) Up to 2 hours/1,000 times Endpoint/Kinetic/Multipoint/Spectral - Minimum 20 seconds (96 well ABS 1 flush) Vertical and horizontal (↓↓, ↓↑, →→, →←) -0.5 ~ 4.0Abs PC control software SF7 (can also be operated on Windows 10 tablets) Upward illumination downward metering Flat bottom transparent AC100 V, 50/60 Hz, max. 240 VA (depending on the combination of measurement functions) CV1% or less (OD1.0) Double monochromator Rotation/linear, 3 intensity levels and rotation speed settings, time 1 to 7,200 seconds 200~1,000nm Wavelength can be set in 1 nm increments
Multi-microplate reader SH-9500 series-Part Number-SH-9500Lab F Fluorescence measurement

SH-9500Lab F Fluorescence measurement

Available upon quote 6, 12, 24, 48, 96, 384 well plates (more than 300 types registered), custom plate compatible (height 23 mm or less) Photomultiplier tube 450 (W) × 500 (D) × 379 (H) mm USB x 1, RS-232C x 1 (both for PC connection) Variable Excitation: 2.5, 5, 10 nm/fluorescence: 20 nm (approx. φ2mm) Xenon flash lamp - Power cable, fuse, USB cable, tools, instruction manual, simple manual, software CD (SF7) Up to 42 kg (depending on combination of measuring functions) Up to 2 hours/1,000 times Endpoint/Kinetic/Multipoint/Spectral 5×10-12mol/l fluorescein Minimum 20 seconds (96 well ABS 1 flush) Vertical and horizontal (↓↓, ↓↑, →→, →←) - PC control software SF7 (can also be operated on Windows 10 tablets) Upward illumination upward metering Flat bottom black AC100 V, 50/60 Hz, max. 240 VA (depending on the combination of measurement functions) - Double monochromator Rotation/linear, 3 intensity levels and rotation speed settings, time 1 to 7,200 seconds 250~850nm (excitation) 300~900nm (fluorescence) Wavelength can be set in 1 nm increments
Multi-microplate reader SH-9500 series-Part Number-SH-9500Lab BF downward fluorescence measurement

SH-9500Lab BF downward fluorescence measurement

Available upon quote 6, 12, 24, 48, 96, 384 well plates (more than 300 types registered), custom plate compatible (height 23 mm or less) Photomultiplier tube 450 (W) × 500 (D) × 379 (H) mm USB x 1, RS-232C x 1 (both for PC connection) Fixed Excitation: 2.5, 5, 10 nm/fluorescence: 20 nm (approx. φ2mm) Xenon flash lamp - Power cable, fuse, USB cable, tools, instruction manual, simple manual, software CD (SF7) Up to 42 kg (depending on combination of measuring functions) Up to 2 hours/1,000 times Endpoint/Kinetic/Multipoint/Spectral - Minimum 20 seconds (96 well ABS 1 flush) Vertical and horizontal (↓↓, ↓↑, →→, →←) - PC control software SF7 (can also be operated on Windows 10 tablets) Downward illumination downward metering Flat bottom black (bottom transparent) AC100 V, 50/60 Hz, max. 240 VA (depending on the combination of measurement functions) - Double monochromator Rotation/linear, 3 intensity levels and rotation speed settings, time 1 to 7,200 seconds 250~850nm (excitation) 300~900nm (fluorescence) Wavelength can be set in 1 nm increments
Multi-microplate reader SH-9500 series-Part Number-SH-9500Lab T Time-resolved fluorescence measurement

SH-9500Lab T Time-resolved fluorescence measurement

Available upon quote 6, 12, 24, 48, 96, 384 well plates (more than 300 types registered), custom plate compatible (height 23 mm or less) Photomultiplier tube 450 (W) × 500 (D) × 379 (H) mm USB x 1, RS-232C x 1 (both for PC connection) Variable Excitation: 2.5, 5, 10 nm/fluorescence: 20 nm (approx. φ2mm) Xenon flash lamp - Power cable, fuse, USB cable, tools, instruction manual, simple manual, software CD (SF7) Up to 42 kg (depending on combination of measuring functions) Up to 2 hours/1,000 times Endpoint/Kinetic/Multipoint/Spectral 7.5×10-12mol/l europium Minimum 20 seconds (96 well ABS 1 flush) Vertical and horizontal (↓↓, ↓↑, →→, →←) - PC control software SF7 (can also be operated on Windows 10 tablets) Upward illumination upward metering Flat bottom black AC100 V, 50/60 Hz, max. 240 VA (depending on the combination of measurement functions) - Double monochromator Rotation/linear, 3 intensity levels and rotation speed settings, time 1 to 7,200 seconds 250~850nm (excitation) 300~900nm (fluorescence) Wavelength can be set in 1 nm increments
Multi-microplate reader SH-9500 series-Part Number-SH-9500Lab C Luminescence measurement

SH-9500Lab C Luminescence measurement

Available upon quote 6, 12, 24, 48, 96, 384 well plates (more than 300 types registered), custom plate compatible (height 23 mm or less) Photon counting 450 (W) × 500 (D) × 379 (H) mm USB x 1, RS-232C x 1 (both for PC connection) Fixed - Xenon flash lamp - Power cable, fuse, USB cable, tools, instruction manual, simple manual, software CD (SF7) Up to 42 kg (depending on combination of measuring functions) Up to 2 hours/1,000 times Endpoint/Kinetic/Multipoint/Spectral 2.5×10-19mol/l ALP Minimum 20 seconds (96 well ABS 1 flush) Vertical and horizontal (↓↓, ↓↑, →→, →←) - PC control software SF7 (can also be operated on Windows 10 tablets) Upward metering Flat bottom black AC100 V, 50/60 Hz, max. 240 VA (depending on the combination of measurement functions) - Total light amount Rotation/linear, 3 intensity levels and rotation speed settings, time 1 to 7,200 seconds 350~650nm -
Multi-microplate reader SH-9500 series-Part Number-SH-9500N(BG) A Absorption measurement

SH-9500N(BG) A Absorption measurement

Available upon quote 96, 384 well plate (height 16mm or less) Silicon photodiode 450 (W) × 500 (D) × 379 (H) mm USB x 1 (for PC connection), RS-232C x 1 (for wireless connection) Fixed 10nm fixed Xenon flash lamp ±0.5 T or ±0.005 Abs (492nm) Power cable, fuse, USB cable, tools, instruction manual, simple manual, software CD (SF7) Maximum 43kg (depending on combination of measurement functions) Up to 2 hours/1,000 times Endpoint/Kinetic/Multipoint/Spectral - Minimum 15 seconds (96 well ABS 1 flush) Vertical and horizontal (↓↓, ↓↑, →→, →←) -0.5 ~ 4.0Abs PC control software SF7 (can also be operated on Windows 10/11 tablets) Upward illumination downward metering Flat bottom transparent AC100 V, 50/60 Hz, max. 200 VA (depending on the combination of measurement functions) CV1% or less (OD1.0) Double monochromator Rotation/linear, 3 intensity levels and rotation speed settings, time 1 to 7,200 seconds 350-750nm Wavelength can be set in 1 nm increments
Multi-microplate reader SH-9500 series-Part Number-SH-9500N(BG) F Fluorescence measurement

SH-9500N(BG) F Fluorescence measurement

Available upon quote 96, 384 well plate (height 16mm or less) Photomultiplier tube 450 (W) × 500 (D) × 379 (H) mm USB x 1 (for PC connection), RS-232C x 1 (for wireless connection) Fixed 10nm fixed (excitation)/20nm fixed (fluorescence) Xenon flash lamp - Power cable, fuse, USB cable, tools, instruction manual, simple manual, software CD (SF7) Maximum 43kg (depending on combination of measurement functions) Up to 2 hours/1,000 times Endpoint/Kinetic/Multipoint/Spectral - Minimum 15 seconds (96 well ABS 1 flush) Vertical and horizontal (↓↓, ↓↑, →→, →←) - PC control software SF7 (can also be operated on Windows 10/11 tablets) Upward illumination upward metering Flat bottom black AC100 V, 50/60 Hz, max. 200 VA (depending on the combination of measurement functions) - Double monochromator Rotation/linear, 3 intensity levels and rotation speed settings, time 1 to 7,200 seconds 350~750nm (excitation) 400~800nm ​​(fluorescence) Wavelength can be set in 1 nm increments
Multi-microplate reader SH-9500 series-Part Number-SH-9500N(BG) C Luminescence measurement

SH-9500N(BG) C Luminescence measurement

Available upon quote 96, 384 well plate (height 16mm or less) Photon counting photomultiplier tube 450 (W) × 500 (D) × 379 (H) mm USB x 1 (for PC connection), RS-232C x 1 (for wireless connection) - - - - Power cable, fuse, USB cable, tools, instruction manual, simple manual, software CD (SF7) Maximum 43kg (depending on combination of measurement functions) Up to 2 hours/1,000 times Endpoint/Kinetic/Multipoint/Spectral 3.5×10-19mol/l ALP Minimum 15 seconds (96 well ABS 1 flush) Vertical and horizontal (↓↓, ↓↑, →→, →←) - PC control software SF7 (can also be operated on Windows 10/11 tablets) Upward metering Flat bottom black AC100 V, 50/60 Hz, max. 200 VA (depending on the combination of measurement functions) - Total light amount Rotation/linear, 3 intensity levels and rotation speed settings, time 1 to 7,200 seconds 350~650nm -

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Corona Electric Co., Ltd.


View more products of Corona Electric Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree