Product
Multi-microplate reader SH-9500 seriesHandling Company
Corona Electric Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Compatible plate | Detector | External dimensions | External terminal | Focus | Half width (irradiation spot diameter) | Light source | Linearity | Main accessories | Mass | Measurement interval, number of times | Measurement method | Measurement sensitivity (96 wells) | Measurement time | Measuring direction | Measuring range | Others | Photometry | Plate color/bottom shape | Power consumption | Reproducibility | Spectroscopic method | Stirring function | Wavelength range | Wavelength resolution |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SH-9500Lab A Absorption measurement |
Available upon quote | 6, 12, 24, 48, 96, 384 well plates (more than 300 types registered), custom plate compatible (height 23 mm or less) | Silicon photodiode | 450 (W) × 500 (D) × 379 (H) mm | USB x 1, RS-232C x 1 (both for PC connection) | Variable | 2.5, 5, 10 nm (about φ1.6mm) | Xenon flash lamp | ±0.5 T or ±0.005 Abs (0 ~ 2.5 Abs) | Power cable, fuse, USB cable, tools, instruction manual, simple manual, software CD (SF7) | Up to 42 kg (depending on combination of measuring functions) | Up to 2 hours/1,000 times | Endpoint/Kinetic/Multipoint/Spectral | - | Minimum 20 seconds (96 well ABS 1 flush) | Vertical and horizontal (↓↓, ↓↑, →→, →←) | -0.5 ~ 4.0Abs | PC control software SF7 (can also be operated on Windows 10 tablets) | Upward illumination downward metering | Flat bottom transparent | AC100 V, 50/60 Hz, max. 240 VA (depending on the combination of measurement functions) | CV1% or less (OD1.0) | Double monochromator | Rotation/linear, 3 intensity levels and rotation speed settings, time 1 to 7,200 seconds | 200~1,000nm | Wavelength can be set in 1 nm increments | |
SH-9500Lab F Fluorescence measurement |
Available upon quote | 6, 12, 24, 48, 96, 384 well plates (more than 300 types registered), custom plate compatible (height 23 mm or less) | Photomultiplier tube | 450 (W) × 500 (D) × 379 (H) mm | USB x 1, RS-232C x 1 (both for PC connection) | Variable | Excitation: 2.5, 5, 10 nm/fluorescence: 20 nm (approx. φ2mm) | Xenon flash lamp | - | Power cable, fuse, USB cable, tools, instruction manual, simple manual, software CD (SF7) | Up to 42 kg (depending on combination of measuring functions) | Up to 2 hours/1,000 times | Endpoint/Kinetic/Multipoint/Spectral | 5×10-12mol/l fluorescein | Minimum 20 seconds (96 well ABS 1 flush) | Vertical and horizontal (↓↓, ↓↑, →→, →←) | - | PC control software SF7 (can also be operated on Windows 10 tablets) | Upward illumination upward metering | Flat bottom black | AC100 V, 50/60 Hz, max. 240 VA (depending on the combination of measurement functions) | - | Double monochromator | Rotation/linear, 3 intensity levels and rotation speed settings, time 1 to 7,200 seconds | 250~850nm (excitation) 300~900nm (fluorescence) | Wavelength can be set in 1 nm increments | |
SH-9500Lab BF downward fluorescence measurement |
Available upon quote | 6, 12, 24, 48, 96, 384 well plates (more than 300 types registered), custom plate compatible (height 23 mm or less) | Photomultiplier tube | 450 (W) × 500 (D) × 379 (H) mm | USB x 1, RS-232C x 1 (both for PC connection) | Fixed | Excitation: 2.5, 5, 10 nm/fluorescence: 20 nm (approx. φ2mm) | Xenon flash lamp | - | Power cable, fuse, USB cable, tools, instruction manual, simple manual, software CD (SF7) | Up to 42 kg (depending on combination of measuring functions) | Up to 2 hours/1,000 times | Endpoint/Kinetic/Multipoint/Spectral | - | Minimum 20 seconds (96 well ABS 1 flush) | Vertical and horizontal (↓↓, ↓↑, →→, →←) | - | PC control software SF7 (can also be operated on Windows 10 tablets) | Downward illumination downward metering | Flat bottom black (bottom transparent) | AC100 V, 50/60 Hz, max. 240 VA (depending on the combination of measurement functions) | - | Double monochromator | Rotation/linear, 3 intensity levels and rotation speed settings, time 1 to 7,200 seconds | 250~850nm (excitation) 300~900nm (fluorescence) | Wavelength can be set in 1 nm increments | |
SH-9500Lab T Time-resolved fluorescence measurement |
Available upon quote | 6, 12, 24, 48, 96, 384 well plates (more than 300 types registered), custom plate compatible (height 23 mm or less) | Photomultiplier tube | 450 (W) × 500 (D) × 379 (H) mm | USB x 1, RS-232C x 1 (both for PC connection) | Variable | Excitation: 2.5, 5, 10 nm/fluorescence: 20 nm (approx. φ2mm) | Xenon flash lamp | - | Power cable, fuse, USB cable, tools, instruction manual, simple manual, software CD (SF7) | Up to 42 kg (depending on combination of measuring functions) | Up to 2 hours/1,000 times | Endpoint/Kinetic/Multipoint/Spectral | 7.5×10-12mol/l europium | Minimum 20 seconds (96 well ABS 1 flush) | Vertical and horizontal (↓↓, ↓↑, →→, →←) | - | PC control software SF7 (can also be operated on Windows 10 tablets) | Upward illumination upward metering | Flat bottom black | AC100 V, 50/60 Hz, max. 240 VA (depending on the combination of measurement functions) | - | Double monochromator | Rotation/linear, 3 intensity levels and rotation speed settings, time 1 to 7,200 seconds | 250~850nm (excitation) 300~900nm (fluorescence) | Wavelength can be set in 1 nm increments | |
SH-9500Lab C Luminescence measurement |
Available upon quote | 6, 12, 24, 48, 96, 384 well plates (more than 300 types registered), custom plate compatible (height 23 mm or less) | Photon counting | 450 (W) × 500 (D) × 379 (H) mm | USB x 1, RS-232C x 1 (both for PC connection) | Fixed | - | Xenon flash lamp | - | Power cable, fuse, USB cable, tools, instruction manual, simple manual, software CD (SF7) | Up to 42 kg (depending on combination of measuring functions) | Up to 2 hours/1,000 times | Endpoint/Kinetic/Multipoint/Spectral | 2.5×10-19mol/l ALP | Minimum 20 seconds (96 well ABS 1 flush) | Vertical and horizontal (↓↓, ↓↑, →→, →←) | - | PC control software SF7 (can also be operated on Windows 10 tablets) | Upward metering | Flat bottom black | AC100 V, 50/60 Hz, max. 240 VA (depending on the combination of measurement functions) | - | Total light amount | Rotation/linear, 3 intensity levels and rotation speed settings, time 1 to 7,200 seconds | 350~650nm | - | |
SH-9500N(BG) A Absorption measurement |
Available upon quote | 96, 384 well plate (height 16mm or less) | Silicon photodiode | 450 (W) × 500 (D) × 379 (H) mm | USB x 1 (for PC connection), RS-232C x 1 (for wireless connection) | Fixed | 10nm fixed | Xenon flash lamp | ±0.5 T or ±0.005 Abs (492nm) | Power cable, fuse, USB cable, tools, instruction manual, simple manual, software CD (SF7) | Maximum 43kg (depending on combination of measurement functions) | Up to 2 hours/1,000 times | Endpoint/Kinetic/Multipoint/Spectral | - | Minimum 15 seconds (96 well ABS 1 flush) | Vertical and horizontal (↓↓, ↓↑, →→, →←) | -0.5 ~ 4.0Abs | PC control software SF7 (can also be operated on Windows 10/11 tablets) | Upward illumination downward metering | Flat bottom transparent | AC100 V, 50/60 Hz, max. 200 VA (depending on the combination of measurement functions) | CV1% or less (OD1.0) | Double monochromator | Rotation/linear, 3 intensity levels and rotation speed settings, time 1 to 7,200 seconds | 350-750nm | Wavelength can be set in 1 nm increments | |
SH-9500N(BG) F Fluorescence measurement |
Available upon quote | 96, 384 well plate (height 16mm or less) | Photomultiplier tube | 450 (W) × 500 (D) × 379 (H) mm | USB x 1 (for PC connection), RS-232C x 1 (for wireless connection) | Fixed | 10nm fixed (excitation)/20nm fixed (fluorescence) | Xenon flash lamp | - | Power cable, fuse, USB cable, tools, instruction manual, simple manual, software CD (SF7) | Maximum 43kg (depending on combination of measurement functions) | Up to 2 hours/1,000 times | Endpoint/Kinetic/Multipoint/Spectral | - | Minimum 15 seconds (96 well ABS 1 flush) | Vertical and horizontal (↓↓, ↓↑, →→, →←) | - | PC control software SF7 (can also be operated on Windows 10/11 tablets) | Upward illumination upward metering | Flat bottom black | AC100 V, 50/60 Hz, max. 200 VA (depending on the combination of measurement functions) | - | Double monochromator | Rotation/linear, 3 intensity levels and rotation speed settings, time 1 to 7,200 seconds | 350~750nm (excitation) 400~800nm (fluorescence) | Wavelength can be set in 1 nm increments | |
SH-9500N(BG) C Luminescence measurement |
Available upon quote | 96, 384 well plate (height 16mm or less) | Photon counting photomultiplier tube | 450 (W) × 500 (D) × 379 (H) mm | USB x 1 (for PC connection), RS-232C x 1 (for wireless connection) | - | - | - | - | Power cable, fuse, USB cable, tools, instruction manual, simple manual, software CD (SF7) | Maximum 43kg (depending on combination of measurement functions) | Up to 2 hours/1,000 times | Endpoint/Kinetic/Multipoint/Spectral | 3.5×10-19mol/l ALP | Minimum 15 seconds (96 well ABS 1 flush) | Vertical and horizontal (↓↓, ↓↑, →→, →←) | - | PC control software SF7 (can also be operated on Windows 10/11 tablets) | Upward metering | Flat bottom black | AC100 V, 50/60 Hz, max. 200 VA (depending on the combination of measurement functions) | - | Total light amount | Rotation/linear, 3 intensity levels and rotation speed settings, time 1 to 7,200 seconds | 350~650nm | - |
Click on the part number for more information about each product