Product
Thyristor type power regulator High-performance unit compatible with network CALPOTEHandling Company
SANSHA ELECTRIC MANUFACTURING CO., LTD.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Accessories (per unit) | Control input | Control method | Current limit | Dielectric strength Dielectric strength voltage | Dielectric strength Insulation resistance | Input specifications Frequency | Input specifications Number of phases | Input specifications Voltage | Operating environment Ambient temperature | Operating environment Relative humidity | Output characteristics | Output specifications Current | Protection | Start/stop method | Usage environment Atmosphere |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
UG1 |
Available upon quote | Variable resistor (1kΩ) x 1pcs, knob x 1pcs |
1. ON/OFF signal A contact that turns ON when the temperature drops below the set temperature. 2.Current signal DC4~20mA (unit input resistance 250Ω) 3.Voltage signal DC1~5V, DC0~5V, etc. |
Phase control Cycle control (continuous type, intermittent type) Cycle control compatible with transformer load (special support UG1 only) |
UG1: Can be set to 10~110% of rated current (Phase control only) (Standard 110%, can be set arbitrarily on the display panel) |
AC2000V/min (100/200V system) AC2500V/min (400V system) |
20MΩ or more (DC500V megger) | 50/60Hz ±5% | Single phase, three phase |
100V series (100/110/120V ±10%) 200V series (200/220/254V ±10%) 400V series (380/400/440/460/480V ±10%) |
Operation: -10~50℃ Storage: -20~70℃ | 30~90%RH |
Linear characteristics ±3% F.S (at output 10~90%) Lower point setting: Setting the lowest value of output voltage Gradient setting: Maximum output voltage setting |
25/35/50/75A (natural cooling) 100/150/250/350/450A (wind cooling) 600/800/1200A (semi-standard/wind cooling) |
1.Overcurrent protection 2.Short circuit protection 3.Overheat protection (rated 100A units or more) |
Soft start/down method 0~300 seconds (Standard 0.5 seconds, can be set arbitrarily on the display panel) |
No corrosive gas, dust, or vibration | |
UF3 |
Available upon quote | Variable resistor (1kΩ) x 1pcs, knob x 1pcs |
1. ON/OFF signal A contact that turns ON when the temperature drops below the set temperature. 2.Current signal DC4~20mA (unit input resistance 250Ω) 3.Voltage signal DC1~5V, DC0~5V, etc. |
Phase control Cycle control (continuous type, intermittent type) Cycle control compatible with transformer load (special support UG1 only) |
UF3: Can be set to 50~110% of rated current (Phase control only) (Standard 110%, can be set arbitrarily on the display panel) |
AC2000V/min (100/200V system) AC2500V/min (400V system) |
20MΩ or more (DC500V megger) | 50/60Hz ±5% | Single phase, three phase |
100V series (100/110/120V ±10%) 200V series (200/220/254V ±10%) 400V series (380/400/440/460/480V ±10%) |
Operation: -10~50℃ Storage: -20~70℃ | 30~90%RH |
Linear characteristics ±3% F.S (at output 10~90%) Lower point setting: Setting the lowest value of output voltage Gradient setting: Maximum output voltage setting |
25/35/50/75A (natural cooling) 100/150/250/350/450A (wind cooling) 600/800/1200A (semi-standard/wind cooling) |
1.Overcurrent protection 2.Short circuit protection 3.Overheat protection (rated 100A units or more) |
Soft start/down method 0~300 seconds (Standard 0.5 seconds, can be set arbitrarily on the display panel) |
No corrosive gas, dust, or vibration |
Click on the part number for more information about each product