Product
Limit switch Rod plunger type limit switchHandling Company
Bestact Solutions Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Ambient temperature Storage | Ambient temperature in use | Approximate mass | Built-in bestact | Connection method | Contact configuration | Insulation resistance | Open contact Rated operating current AC | Open contact Rated operating current DC | Open contact initial contact resistance | Open contact maximum breaking current | Open contact minimum operating current | Open contact rated current carrying current | Operating power | Protective structure | Rated insulation voltage | Shock malfunction | Vibration resistant malfunction | Withstand voltage (50/60Hz) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PSPD-07G20 |
Available upon quote | -10~+60℃ | -10~+60℃ | 70g | R25 | Screw terminal (M4×6) | 2a contact | 20MΩ or more (DC500V megger) | - | - | - | - | - | - | Initial pressure: 3.2N±1N, Final pressure: 5.5N±2N (stroke 6.5mm) | IP50 equivalent | AC250V (50/60Hz) | JIS E 4031 Annex JB Type 1A reference | JIS E 4031 Annex JA Type 1A reference |
Between contacts: AC500V, 1 minute Between earth: AC1,500V, 1 minute |
|
PSPD-07G11 |
Available upon quote | -10~+60℃ | -10~+60℃ | 70g | R25 | Screw terminal (M4×6) | 1a1b contacts | 20MΩ or more (DC500V megger) | - | - | - | - | - | - | Initial pressure: 3.2N±1N, Final pressure: 5.5N±2N (stroke 6.5mm) | IP50 equivalent | AC250V (50/60Hz) | JIS E 4031 Annex JB Type 1A reference | JIS E 4031 Annex JA Type 1A reference |
Between contacts: AC500V, 1 minute Between earth: AC1,500V, 1 minute |
|
PSPD-07G02 |
Available upon quote | -10~+60℃ | -10~+60℃ | 70g | R25 | Screw terminal (M4×6) | 2b contact | 20MΩ or more (DC500V megger) | - | - | - | - | - | - | Initial pressure: 3.2N±1N, Final pressure: 5.5N±2N (stroke 6.5mm) | IP50 equivalent | AC250V (50/60Hz) | JIS E 4031 Annex JB Type 1A reference | JIS E 4031 Annex JA Type 1A reference |
Between contacts: AC500V, 1 minute Between earth: AC1,500V, 1 minute |
|
PPMU-G40 |
Available upon quote | -10~+60℃ | -10~+60℃ | 120g | R25 | Screw terminal (M4×8) | 4a contact | 20MΩ or more (DC500V megger) | - | - | - | - | - | - | Initial pressure: 2.9N±1N, Final pressure: 4.9N±2N (stroke 7mm) | IP50 equivalent | AC250V (50/60Hz) | JIS E 4031 Annex JB Type 2 B reference | JIS E 4031 Annex JA Type 2 B reference |
Between contacts: AC500V, 1 minute Between earth: AC1,500V, 1 minute |
|
PPMU-G31 |
Available upon quote | -10~+60℃ | -10~+60℃ | 120g | R25 | Screw terminal (M4×8) | 3a1b contacts | 20MΩ or more (DC500V megger) | - | - | - | - | - | - | Initial pressure: 2.9N±1N, Final pressure: 4.9N±2N (stroke 7mm) | IP50 equivalent | AC250V (50/60Hz) | JIS E 4031 Annex JB Type 2 B reference | JIS E 4031 Annex JA Type 2 B reference |
Between contacts: AC500V, 1 minute Between earth: AC1,500V, 1 minute |
|
PPMU-G22 |
Available upon quote | -10~+60℃ | -10~+60℃ | 120g | R25 | Screw terminal (M4×8) | 2a2b contacts | 20MΩ or more (DC500V megger) | - | - | - | - | - | - | Initial pressure: 2.9N±1N, Final pressure: 4.9N±2N (stroke 7mm) | IP50 equivalent | AC250V (50/60Hz) | JIS E 4031 Annex JB Type 2 B reference | JIS E 4031 Annex JA Type 2 B reference |
Between contacts: AC500V, 1 minute Between earth: AC1,500V, 1 minute |
|
PPMU-G13 |
Available upon quote | -10~+60℃ | -10~+60℃ | 120g | R25 | Screw terminal (M4×8) | 1a3b contacts | 20MΩ or more (DC500V megger) | - | - | - | - | - | - | Initial pressure: 2.9N±1N, Final pressure: 4.9N±2N (stroke 7mm) | IP50 equivalent | AC250V (50/60Hz) | JIS E 4031 Annex JB Type 2 B reference | JIS E 4031 Annex JA Type 2 B reference |
Between contacts: AC500V, 1 minute Between earth: AC1,500V, 1 minute |
|
PPMU-G04 |
Available upon quote | -10~+60℃ | -10~+60℃ | 120g | R25 | Screw terminal (M4×8) | 4b contact | 20MΩ or more (DC500V megger) | - | - | - | - | - | - | Initial pressure: 2.9N±1N, Final pressure: 4.9N±2N (stroke 7mm) | IP50 equivalent | AC250V (50/60Hz) | JIS E 4031 Annex JB Type 2 B reference | JIS E 4031 Annex JA Type 2 B reference |
Between contacts: AC500V, 1 minute Between earth: AC1,500V, 1 minute |
|
PPMU-E□□C |
Available upon quote | -20~+80℃ | -20~+80℃ | 250g | R15 | Screw terminal (M4×8) | 1db + Bestact contact (5 contacts in total, A contact and B contact) | 100MΩ or more (DC500V megger) |
250V, 3A *Indicates the current value that can be applied continuously without breaking the contact and leaving the circuit in a closed state without causing the temperature rise to exceed the specified value. |
110V, 0.5A (time constant 100ms) *Indicates the current value that can be applied continuously without breaking the contact and leaving the circuit in a closed state without causing the temperature rise to exceed the specified value. |
100mΩ | 110V, 5A (time constant 100ms) | DC100V 10mA | 5A continuous | Initial pressure: 2.9N±1N, Final pressure: 7.8N±2N (stroke 9mm) | Equivalent to IP50 (excluding 1db contact part) | AC250V (50/60Hz) | JIS E 4031 Annex JB Type 2 B reference | JIS E 4031 Annex JA Type 2 B reference |
Between contacts: AC800V, 1 minute Between earth: AC2,500V, 1 minute |
Click on the part number for more information about each product