Product
Combustible gas detector Cosmotector seriesHandling Company
Youpi Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Alarm method | Alarm setting value | Continuous use time | Detection principle | Detection range | Explosion-proof structure | External dimensions (mm) | Gas sampling method | Gas to be detected | Indication accuracy | Operating temperature range | Option | Power supply | Standard accessories | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
XP-3110 |
Available upon quote |
Gas alarm: Buzzer, red lamp flashing Failure alarm: Buzzer, flashing red lamp, LCD display |
20%LEL |
When using alkaline batteries: Approximately 20 hours (approximately 15 hours with methane specification) (With no alarm, 20℃, backlight OFF) |
Catalytic combustion type | 0~100%LEL | Exibd II CT3 | W82×H162×D36 | Automatic suction type |
Flammable gases and vapors of flammable solvents *Please specify the target gas. |
±5% of full scale | -20~50℃ (0~40℃ except for isobutane specifications) | Gas introduction pipe, mixer, log data collection set (CD-ROM software + USB cable), AC adapter | 4 AA alkaline batteries |
Leather case, 4 AA alkaline batteries, gas introduction tube (1m), Drain filter, filter element, suction pipe, rubber for suction pipe |
Approximately 450g (excluding battery) | |
XP-3140 |
Available upon quote |
Gas alarm: Buzzer, red lamp flashing Failure alarm: Buzzer, flashing red lamp, LCD display |
50vol% |
When using alkaline batteries: Approximately 30 hours (With no alarm, 20℃, backlight OFF) |
Gas heat conduction type | 0~100vol% | Exibd II CT3 | W82×H162×D36 | Automatic suction type | Methane, propane, argon, carbon dioxide, etc. |
H range: ±5% of full scale L range: ±10% of full scale |
0~40℃ | Gas introduction pipe, mixer, log data collection set (CD-ROM software + USB cable), AC adapter | 4 AA alkaline batteries |
Leather case, 4 AA alkaline batteries, gas introduction tube (1m), Drain filter, filter element, suction pipe, rubber for suction pipe |
Approximately 450g (excluding battery) | |
XP-3160 |
Available upon quote |
Gas alarm: Buzzer, red lamp flashing Failure alarm: Buzzer, flashing red lamp, LCD display |
250ppm or 500ppm |
When using alkaline batteries: Approximately 20 hours (approximately 15 hours with methane specification) (With no alarm, 20℃, backlight OFF) |
Catalytic combustion type | 0~5,000ppm or 0~10,000ppm | Exibd II CT3 | W82×H162×D36 | Automatic suction type |
Flammable gases and vapors of flammable solvents *Please specify the target gas. |
H range: ±5% of full scale L range: ±10% of full scale |
-20~50℃ (0~40℃ except for isobutane specifications) | Gas introduction pipe, mixer, log data collection set (CD-ROM software + USB cable), AC adapter | 4 AA alkaline batteries |
Leather case, 4 AA alkaline batteries, gas introduction pipe (1m), drain filter, Filter element, suction pipe, rubber for suction pipe |
Approximately 450g (excluding battery) |
Click on the part number for more information about each product