Product
Ideal for automating earth continuity tests with constant current method Earth continuity tester TOS6200AHandling Company
Kikusui Electronics Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | Output ammeter accuracy | Output ammeter hold function | Output ammeter measurement range | Output ammeter resolution | Output ammeter response | Output section Maximum rated output | Output section Output method | Output section current setting range | Output section distortion rate | Output section frequency | Output section open terminal voltage | Output voltmeter Offset cancellation function | Output voltmeter accuracy | Output voltmeter hold function | Output voltmeter measurement range | Output voltmeter resolution | Output voltmeter response | Pass/Fail Judgment Function Calibration | Pass/Fail Judgment Function Judgment Accuracy | Pass/Fail Judgment Function Judgment method based on resistance value | Pass/Fail Judgment Function Judgment method based on sampling voltage value | Pass/Fail Judgment Function LED | Pass/Fail Judgment Function Lower Reference Value (LOWER) Setting Range | Pass/Fail Judgment Function Resolution | Pass/Fail Judgment Function Upper Reference Value (UPPER) Setting Range | Resistance meter accuracy | Resistance meter hold function | Resistance meter measurement range | Resistance meter offset cancel function | Resistance meter resolution |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TOS6200A |
Available upon quote | ± (1% of reading +0.2A) | The measured current value at the end of the test is held during the PASS and FAIL periods. | 0.0Aac~33.0Aac | 0.1A | Average value response/effective value display (response time 200ms) | 150VA (at output terminal) | PWM switching method |
3.0Aac~31.0Aac (For resistors whose output is below the maximum rated output and whose output terminal voltage is 5.4V or below) Resolution: 0.1A Accuracy: ± (1% of setting + 0.2A) |
2% or less (at 0.1Ω pure resistive load of 10A or more) | 50Hz/60Hz sine wave (selectable) Accuracy: ±200ppm | 6Vrms or less | 0.000V~5.40V (with OFF function) | ± (1% of reading + 0.02V) | The measured voltage value at the end of the test is held during the PASS and FAIL periods. | 0.00Vac~6.00Vac | 0.01V | Average value response/effective value display (response time 200ms) | Calibration with sine wave rms value using pure resistive load | ± (2% of UPPER + 0.003Ω) |
Window comparator method ・Determined as FAIL when a resistance value higher than the upper limit reference value is detected. ・Determined as FAIL when a resistance value below the lower limit reference value is detected. ・When judged as FAIL, output is cut off and a FAIL signal is generated. |
Window comparator method ・Determined as FAIL when a voltage value higher than the upper limit reference value is detected. ・Determined as FAIL when a voltage value below the lower limit reference value is detected. ・When judged as FAIL, output is cut off and a FAIL signal is generated. |
PASS: Lights up for about 0.2 seconds or more when judged as PASS, lights continuously when set to PASS HOLD | 0.001Ω~1.200Ω | 0.001Ω | 0.001Ω~1.200Ω | ± (2% of reading + 0.003Ω) | The measured resistance value at the end of the test is held during the PASS period. | 0.001Ω~1.200Ω | 0.000Ω~1.200Ω (with OFF function) | 0.001Ω |