Earth continuity tester TOS6210 capable of UL60950-1 40A/60A testingHandling Company
Kikusui Electronics Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | Judgment method based on resistance value Lower reference value LOWER setting range | Judgment method based on resistance value Upper reference value UPPER setting range | Judgment method based on sampling voltage value Resolution | Judgment method based on voltage value Lower reference value LOWER setting range | Judgment method based on voltage value Upper reference value UPPER setting range | Output ammeter hold function | Output ammeter measurement range | Output ammeter resolution/accuracy | Output ammeter response | Output section Current setting range Accuracy | Output section Current setting range Resolution | Output section Maximum rated output | Output section Output method | Output section current setting range | Output section distortion rate | Output section frequency accuracy | Output section open terminal voltage | Output voltmeter Offset cancellation function | Output voltmeter hold function | Output voltmeter measurement range | Output voltmeter resolution/accuracy | Output voltmeter response | Pass/Fail Judgment Function Judgment method based on resistance value | Pass/Fail Judgment Function Judgment method based on sampling voltage value | Pass/fail judgment function Judgment method based on resistance value Judgment accuracy | Pass/fail judgment function Judgment method based on resistance value Resolution | Resistance meter hold function | Resistance meter measurement range | Resistance meter offset cancel function | Resistance meter resolution/accuracy |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TOS6210 |
Available upon quote | 0.001Ω~0.600Ω | 0.001Ω~0.600Ω | 0.01V | 0.01V~5.40V | 0.01V~5.40V | The measured current value at the end of the test is held during the PASS and FAIL periods. | AC 0.0A ~ 66.0A | 0.1A/± (1% of reading +0.4A) | Average value response/effective value display (response time 200ms) | ± (1% of setting +0.4A) | 0.1A | 220VA (at output terminal) | PWM switching method |
AC 6.0A ~ 62.0A (If the resistance is below the maximum rated output and the output terminal voltage is 5.4V or below) |
2% or less (for 0.1Ω pure resistive load of 20A or more) | ±200ppm | 6Vrms or less | 0.00V ~ 5.40V (with OFF function) | The measured voltage value at the end of the test is held during the PASS and FAIL periods. | AC 0.00V ~ 6.00V | 0.01V/± (1% of reading +0.02V) | Average value response/effective value display (response time 200ms) |
Window comparator method ・Determined as FAIL when a resistance value higher than the upper limit reference value is detected. ・Determined as FAIL when a resistance value below the lower limit reference value is detected. ・When judged as FAIL, output is cut off and a FAIL signal is generated. |
Window comparator method ・Determined as FAIL when a voltage value higher than the upper limit reference value is detected. ・Determined as FAIL when a voltage value below the lower limit reference value is detected. ・When judged as FAIL, output is cut off and a FAIL signal is generated. |
± (2% of UPPER + 0.003Ω) | 0.001Ω | The measured resistance value at the end of the test is held during the PASS and FAIL periods. | 0.001Ω ~ 0.600Ω | 0.000Ω ~ 0.600Ω (with OFF function) | 0.001Ω/± (2% of reading + 0.003Ω) |