De facto standard AC withstanding voltage tester TOS5200 built on trust and track recordHandling Company
Kikusui Electronics Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | AC output section Output method | AC output section Output range Setting accuracy | AC output section Output range Setting range | AC output section Output range Setting resolution | AC output section Output voltage waveform Distortion rate | AC output section crest factor | AC output section frequency | AC output section frequency accuracy | AC output section input voltage fluctuation | AC output section maximum rated current | AC output section maximum rated output | AC output section maximum rated voltage | AC output section output range | AC output section output voltage waveform | AC output section short circuit current | AC output section transformer capacity | AC output section voltage fluctuation rate | Ammeter digital accuracy | Ammeter digital display | Ammeter digital hold function | Ammeter digital measurement range | Ammeter digital response | Limit voltage value (Limit Voltage) | Output voltage monitoring function | Start Voltage | Voltmeter digital accuracy | Voltmeter digital display | Voltmeter digital hold function | Voltmeter digital measurement range | Voltmeter digital response |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TOS5200 |
Available upon quote | PWM switching method | ± (2 % of set + 20 V) (at no load) | 0.00kV ~ 5.50kV | 10V STEP | Output voltage 0.5 kV or more: 3% or less (at no load and with pure resistive load) | Within √2 ± 3 % (output voltage 800 V or more, no load) | 50Hz/60Hz | ± 0.5% (excluding during voltage rise) | ±0.3 % (5 kV no load, power supply voltage 90 V ~ 250 V) | 100 mA (output voltage 0.5 kV or more) | 500VA (5kV/100mA) | 5 kV | 0.05 kV ~ 5.00 kV | Sine wave | 200 mA or more (output voltage 1.0 kV or more) | 500VA | 10% or less (maximum rated load → no load) | 1.00 mA ≦ i: ± (1.5 % of reading), i < 1.00 mA: ± (1.5 % of reading + 30 μA) |
I = measurement current i < 1 mA: □ . □□□ mA 1 mA ≦ i < 10 mA: □ . □□□ mA 10mA ≦ i < 100 mA: □□ . □□ mA |
The measured current value at the end of the test is held during the PASS period. | AC: 0.00mA ~ 110mA | True rms value/average value response rms value display switchable | Upper limit reference value for test voltage setting can be set AC: 0.00 kV ~ 5.50 kV | If the output voltage exceeds the set value (± 350 V), the output is cut off and a protective operation is performed. | The voltage at the start of the withstanding voltage test can be set to 50% of the set voltage. | V < 500 V: ± (1.5 % of reading + 20 V), V ≥ 500 V: ±1.5 % of reading | □ . □□□ kV | The measured voltage value at the end of the test is held during the PASS and FAIL periods. | 0.000 kV ~ 6.500 kV AC | True rms value/average value response rms value display switchable |