Product
Slip ring type 6-component axle force measurement system Ultra-compact 6-component axle force measuring device MFT-306Handling Company
Tokyo Measuring Instruments Laboratory Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | 6 component force voltage output filter | 6 component force voltage output output | 6 component force voltage output output accuracy | Calibration output Output accuracy | Calibration output Output value | Display | External dimensions/mass | Input section Adaptive sensor | Input section Balance adjustment range | Input section Encoder pulse | Input section Measuring range | Input section Number of input points | Input section bridge power supply | Input section response frequency | Interface | Interface Communication condition baud rate | Interface Function | Interface control | Interface data length | Interface parity | Interface stop bit | Interference correction section Interference correction range | Offset position correction section Offset setting range | Operating temperature and humidity range | Power supply | Stability Sensitivity | Stability zero point | Tire rotation speed Output accuracy | Tire rotation speed output Output | Vibration resistance Vibration |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MFT-306 |
Available upon quote | 20,50,100Hz,PASS (vessel type) | 0~5V or -5~+5V (configurable) | ±0.2%FS | ±0.2%FS | -5V, 0V, +5V (when set to ±5V), 0V, 2.5V, 5V (when set to 0~5V) | LED (power status) | 160 (W) ×25 (H) ×75 (D) mm, excluding protrusions/approx. 500g | Strain gauge type 6-component force load cell SLW-NC | ±2,000×10^-6 strain | 360 pulses/rev. (A phase, B phase), 1 pulse/rev. (Z phase) | ±8,000×10^-6 strain | 6 points (strain gauge type transducer) | DC4.8V | DC~400Hz (-3dB±1dB) | RS-232C | 19,200bps | Setting and monitoring measurement conditions | None | 8 bit | None | 1 bit | ±12.7%RO or less | -100~+200mm | 0~+50℃, 85%RH or less (excluding condensation) | DC10~16V 1A MAX. | ±0.2%/℃ | ±1×10^-6 strain/℃ | ±0.5%FS | 0~5V | 29.4m/s^2 |