Strain calibrator CBA-2310AHandling Company
Tokyo Measuring Instruments Laboratory Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | AC power maximum power consumption | AC power supply allowable voltage | AC power supply rated voltage | Applicable bridge configuration | Bridge applied voltage | Bridge resistance | Calibration value 100k range | Calibration value 10k range | Calibration value accuracy (23℃±3℃) Constant current DC bridge power supply | Calibration value accuracy (23℃±3℃) Constant voltage 20kHz bridge power supply | Calibration value accuracy (23℃±3℃) Constant voltage 5kHz bridge power supply | Calibration value accuracy (23℃±3℃) Constant voltage DC bridge power supply | Calibration value shift | Calibration value stability 20kHz bridge power supply | Calibration value stability 5kHz bridge power supply | Calibration value stability DC bridge power supply | Calibration voltage generation section Calibration value stability | Calibration voltage generator Calibration value | Calibration voltage generator accuracy (23℃±3℃) | Calibration voltage generator output current | Calibration voltage generator output resistance | Channel-to-channel isolation | External dimensions | Interface | Mass | Number of output points | Operating temperature and humidity range | Output offset voltage (23℃±3℃) | Output offset voltage stability | Range switching |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CBA-2310A |
Available upon quote | 72VA MAX | AC85~250V 50/60Hz | AC100~240V 50/60Hz | 4 gauge method |
・DC bridge power supply: 10V DC max. ・5kHz bridge power supply: 5Vrms max. ・20kHz bridge power supply: 2Vrms max. |
・Input (A-C): 120Ω, 350Ω switchable ・Output (between B-D): 105Ω±20Ω |
± (10,001~109,999) ×10^ー6 strain (1×10^ー6 strain step) | 0~±10,000.9×10^-6 strain (0.1×10^-6 strain step) |
・10k range: ± (0.05% of setting+0.2×10^-6 strain) ・100k range: ± (0.05% of setting+2×10^-6 strain) |
± (3% of setting+0.3×10^-6 strain) | ± (0.2% of setting+0.2×10^-6 strain) |
・10k range: ± (0.01% of setting+0.2×10^-6 strain) ・100k range: ± (0.01% of setting+2×10^-6 strain) |
±999.0×10^-6 strain | ± (200ppm of setting+0.3×10^-6 strain) /℃ | ± (20ppm of setting+0.05×10^-6 strain) /℃ | ± (10ppm of setting+0.02×10^-6 strain) /℃ | ± (20PPM of setting+12μV) /℃ | 0~±10.5V (recommended setting) or 0~±21V (0.1mV step) | ± (0.02% of setting+100μV) | ±50mA MAX (all channels total) | 0.5Ω MAX | Non-insulated | 330 (W) × 130 (H) × 240 (D) mm | GP-IB | Approximately 6kg | Strain output: 10 points, voltage output: 10 points | 0~+50℃, 85%RH or less (excluding condensation) |
・10k range: ±2μV ・100k range: ±4μV |
・10k range: ±0.01μV/℃ ・100k range: ±0.1μV/℃ |
Automatic |