ABBEMAT digital heavy duty line that can withstand severe operation conditions-157671
ABBEMAT digital heavy duty line that can withstand severe operation conditions-Anton Paar GmbH

ABBEMAT digital heavy duty line that can withstand severe operation conditions
Anton Paar GmbH


About This Product

■ These devices that can withstand severe operation conditions ・ The heavy duty line refraction meter is assumed to measure the refractive index for severe environment and special applications. These devices that can withstand strict operating conditions use aluminum sealed cage. ABBEMAT 450/650 The refractive is extremely robust and waterproof (IP68). When measuring a sample containing solid particles and bubbles, it is possible to prevent precipitation and random that affects the measurement results by placing abbemat horizontally. ・ Because the control unit is independent, it can be operated in a remote place. ■ Main functions ・ Unlimited performance -highly reliable results in a few seconds ・ "Measurements that have been given up are possible" ・ Ideal solution for quality control and concentration measurement ・ Design to ensure consistency ■ Related products ・ Digital performance bending meter: Abbemat ・ Multiple flexion meter: Abbemat MW * 1 Effective under standard conditions for refractive index measurement (temperature 20 ° C, wavelength 589 nm, peripheral temperature 23 ° C)

  • Product

    ABBEMAT digital heavy duty line that can withstand severe operation conditions

Share this product


250+ people viewing

Last viewed: 5 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

2 Models of ABBEMAT digital heavy duty line that can withstand severe operation conditions

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Accuracy * 1 BRIX (%) Accuracy * 1 Repeated accuracy (ND) Accuracy * 1 Temperature (℃) Accuracy * 1 Temperature stability (℃) Accuracy * 1 refractive index (ND) Calibration Liquid part material Measurement range BRIX (%) Measurement range refractive index (ND) Measurement range temperature (℃) Measurement time per sample Method Minimum sample amount Prism material Resolution BRIX Resolution refractive index (ND) Resolution temperature Temperature control speed User interface interface light source size wavelength weight
ABBEMAT digital heavy duty line that can withstand severe operation conditions-Part Number-157671

157671

Available upon quote ± 0.05 ± 0.0001 ± 0.05 ± 0.002 ± 0.0001 1 point school, 2 point school. Artificial sapphire, FFKM, PPS-GF40, PTFE/ETFE, silicon, alumite 0 ~ 100 1.26 ~ 1.72 4 (maximum surrounding temperature 30 ° C) ~ 125 5 seconds (after temperature equilibrium) Sugar content, chemistry, food and beverages, pharmaceuticals, fragrances and fragrances, medicine, petroleum, and Anton pearl continue to collect and develop new methods and applications through close cooperation with customers. Approximately 0.2 ml Synthetic sapphire 0.01 ± 0.00001 0.01 20 seconds (controlled 0.5 ml of water to 20.00 ° C under the lab condition) Independent control unit RS-232 (PC), Can Bus, Ethernet, VGA LED, average life expectancy: 100,000 hours or more Control unit: width: 220 mm, vertical: 100 mm, depth: 295 mm
Measurement unit: width: 200 mm, vertical: 135 mm, depth: 200 mm
589.3 ± 0.1 nm (sodium D) Control unit: 2.4 kg
Measurement unit: 6.1 kg
ABBEMAT digital heavy duty line that can withstand severe operation conditions-Part Number-157670

157670

Available upon quote ± 0.015 ± 0.000002 ± 0.03 ± 0.002 ± 0.00002 1 point school, 2 point school. Artificial sapphire, FFKM, PPS-GF40, PTFE/ETFE, silicon, alumite 0 ~ 100 1.26 ~ 1.72 4 (maximum surrounding temperature 30 ° C) ~ 125 5 seconds (after temperature equilibrium) Sugar content, chemistry, food and beverages, pharmaceuticals, fragrances and fragrances, medicine, petroleum, and Anton pearl continue to collect and develop new methods and applications through close cooperation with customers. Approximately 0.2 ml YAG (Iet Rium Alminium Garnet) 0.001 ± 0.00001 0.01 20 seconds (controlled 0.5 ml of water to 20.00 ° C under the lab condition) Independent control unit RS-232 (PC), Can Bus, Ethernet, VGA LED, average life expectancy: 100,000 hours or more Control unit: width: 220 mm, vertical: 100 mm, depth: 295 mm
Measurement unit: width: 200 mm, vertical: 135 mm, depth: 200 mm
589.3 ± 0.1 nm (sodium D) Control unit: 2.4 kg
Measurement unit: 6.1 kg

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Anton Paar GmbH


View more products of Anton Paar GmbH

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree