The accuracy of 0.05 kg/m³ in density measurement, 0.1 m/s for sound speed measurement is realized density and sound speed integrated sensor L-com500-181263
The accuracy of 0.05 kg/m³ in density measurement, 0.1 m/s for sound speed measurement is realized density and sound speed integrated sensor L-com500-Anton Paar GmbH

The accuracy of 0.05 kg/m³ in density measurement, 0.1 m/s for sound speed measurement is realized density and sound speed integrated sensor L-com500
Anton Paar GmbH


About This Product

■ Density and sound speed sensor integrated into one unit The accuracy of 0.05 kg/m³ in density measurement and 0.1 m/s is achieved by sound speed measurement. As a result, the concentration measurement of the 3 component mixture can be performed with one unit. It is a concentration sensor that meets a wide range of applications such as chemistry, beverages, and pharmaceuticals. ■ Features ・ High -precision concentration sensor ・ 3 Ideal for measuring mixture of ingredients ・ Because it is module type and compact, it is possible to minimize the effort and cost of integration. ・ Easy test run and operation ・ No consumables, no maintenance required ■ Measure 3 ingredients mixture with one concentration sensor ・ L-DENS 7500 Density sensor and L-SONIC sound speed sensor can be installed in one unit, and 3 ingredients can be measured in each industry. ・ L-com 5500 corresponding to a wide range of applications ・ Brewery: Measurement of beer alcohol concentration and extract concentration ・ Chemical industry: formaldehyde in formaldehyde-methanol-measurement of water concentration (explosion-proof specifications are used for this purpose) ■ Stable accuracy and reliability even under the changing process conditions ・ The highest accuracy of the market ・ Density measurement: 0.05 kg/m³ ・ Sound speed measurement: 0.1 m/s ・ The outstanding metal sensor technology does not have a defect temperature due to plastic coating, and can be accurately measured for temperature fluctuations. ■ 3 can be installed with one unit ・ Because there is no movable part, no maintenance or consumables are required ・ Due to module design, a concentration sensor can be installed at low cost ・ Flexible installation such as inline, bypass, tank, etc. ・ If the flow rate fluctuates extremely or does not flow, uses a small pump (built -in equipment unit) controlled by the device itself. ・ It can be used even in dangerous places by using inline pump 300 EX D ■ Easy test run, simple operation ・ The concentration sensor is connected to the display conversion machine MPDS 5 or the output module pico 3000 is used. ・ You can select a communication protocol according to your needs ・ Measure immediately after installation ■ Expert supports ・ Expert teams have developed solutions for all applications, taking advantage of deep industry knowledge ・ Utilize the know -how of databases and applications that covers a wide range of industries ・ If you are not in the database, you can send a sample to develop a custom -made calibration line that meets your needs. ■ Related products ・ L-Dens ・ L-SONIC

  • Product

    The accuracy of 0.05 kg/m³ in density measurement, 0.1 m/s for sound speed measurement is realized density and sound speed integrated sensor L-com500

Share this product


200+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

1 Models of The accuracy of 0.05 kg/m³ in density measurement, 0.1 m/s for sound speed measurement is realized density and sound speed integrated sensor L-com500

Product Image Part Number Price (excluding tax) Accuracy (density) within the adjustment range Dimensions: Explosion -proof specification (depth x width x height) Dimensions: Non -explosion -proof specifications (depth x width x height) Explosion -proof specification Materials of welcome part Measurement range Peripheral temperature (non -explosion -proof specification) Process absolute pressure Process connection Process temperature Recommended flow rate Repeated accuracy within the adjustment range (speed of sound) Standard adjustment range (density) Standard adjustment range (sound speed) communication
The accuracy of 0.05 kg/m³ in density measurement, 0.1 m/s for sound speed measurement is realized density and sound speed integrated sensor L-com500-Part Number-181263

181263

Available upon quote 0.05 kg/m³ 258 x 156 x 214 mm 258 x 142 x 192 mm ATEX, IECEX, CQPSUS, InMetro Alloy C-276 Up to 2,000 kg/m³, 800 ~ 2,000 m/s -25 ~+65 ℃ (not included with pico 3000) Up to 50 BAR Inline, bypass, tank installation adapter, flange: EN, anSI, JIS, TRI-CLAMP, Varivent®, G 3/8 inch, 12 mm outer diameter (others are corresponding to requests) -25 ~+125 ° C (145 ° C for less than 30 minutes) 100 ~ 500 L/h 0.01 m/s 700 ~ 1,200 kg/m³ 800 ~ 2,000 m/s Can be combined with PICO 3000, PICO 3000 RC, PDS 5