Analyzing alcoholic beverages by button operation alcoholic meter package drink analyzer PBA-PBA 1001 Beer
Analyzing alcoholic beverages by button operation alcoholic meter package drink analyzer PBA-Anton Paar GmbH

Analyzing alcoholic beverages by button operation alcoholic meter package drink analyzer PBA
Anton Paar GmbH


About This Product

■ Final quality warranty in 3 minutes ・ Since all major parameters are measured directly from the final package, production management can be enhanced while convincing the quality of the final product. ・ At the time of the storage tank, check the consistency between batches and then check after bottling to conform to legal requirements. In addition, the problem of the performance of the filling device can be immediately detected and the filling process can be optimized. ・ Since one package beverage analyzer can analyze all quality parameters at the same time, the analysis time is only 3 minutes (more than 9 times the conventional method). ■ Selectally measure alcohol and CO2 ・ Measure alcohol and CO2 on your own measurement principle. Alcohol content can be selected selectively with the Alcolyzer, the most advanced Alcolyzer of Anton Pearl, and CO2 can be selectively measured without being affected by other ingredients. ・ By increasing the certainty of tax filing based on alcohol content and CO2 concentration, accurately grasping the CO2 concentration for each beer style without a sample pre -treatment, providing a taste experience that is not comparable to consumers. Masu. ■ No prior treatment of sample is required ・ By directly pressing the sample, you can eliminate the possibility of pollution of the sample, the use of glass equipment, and the pollution of the product. Since the operator does not need to touch the sample, the reliability of the analysis results is guaranteed. ・ You can transfer the sample directly simply by setting the final package such as cans, bottles, plastic bottles in the PFD filling device. It supports any closing package. ■ Easy proofreading and adjustments that do not depend on products It can be easily calibrated and adjusted with only water and alcohol aqueous solution. The proofreading and adjustment procedures are fully instructed. Since there is no need to calibrate by product, all samples can be measured immediately, and new recipes are not difficult. ■ Equipmentable individual system setup ・ Because of the module type, you can configure an ideal measurement solution, including the necessary parameters. With one measurement cycle, all necessary quality parameters can be analyzed from one sample of one system and minimizing the complexity of the lab. -The system can be selected from 30 or more parameters and can be upgraded at any time.

  • Product

    Analyzing alcoholic beverages by button operation alcoholic meter package drink analyzer PBA

Share this product


370+ people viewing

Last viewed: 4 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

4 Models of Analyzing alcoholic beverages by button operation alcoholic meter package drink analyzer PBA

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Communication interface Convenient function Internal storage capacity Measurement range (optional) Measurement range CO2 concentration Measurement range O2 concentration Measurement range alcohol Measurement range density Measurement range operation pressure Measurement range original extract Measurement range pH value Measurement range temperature Measurement range turbidity Measurement time per sample Minimum sample amount per measurement Repeated accuracy standard deviation CO2 concentration Repeated accuracy standard deviation TPO concentration Repeated accuracy standard deviation alcohol Repeated accuracy standard deviation color degree Repeated accuracy standard deviation density Repeated accuracy standard deviation original extract Repeated accuracy standard deviation turbidity Standard deviation PH value of repeated accuracy Standard deviation extract of repeated accuracy Standard deviation of repeated accuracy O2 concentration Standard deviation temperature of repeated accuracy Standard sample loopput System operation display power supply
Analyzing alcoholic beverages by button operation alcoholic meter package drink analyzer PBA-Part Number-PBA 1001 Beer

PBA 1001 Beer

Available upon quote USB x 5, Ethernet, CAN, RS232 U-View ™, FillingCheck ™, ThermoBalance ™, full-range viscosity correction, Ultrafast measurement mode Measurement values ​​of 10,000 or more with camera image 0 ~ 120EBC 35 ° C: 0 ~ 5.5Vol. 0 ~ 4ppm 0 ~ 12%v/v 0 ~ 3g/cm³ 5 ~ 6.5bar (absolute pressure) 0 ~ 30 ° Plato PH 0 ~ 14 15 ℃ / 20 ℃ 0 ~ 10EBC / 0 ~ 400NTU 3 minutes (including filling) 150 0.03vol. (0.05g/L) - 0.05 0.1 0.00001 0.1 0.02ebc / 0.08ntu PH 3 ~ 7: 0.02 0.025 Less than 200 ppb: 2PPB 0.02 15 sample/h Touch screen, options (keyboard, mouse, barcode reader) 10.1 inch, TFT WXGA (1,280 x 800px), PCAP touch screen AC 100-240V, 50/60Hz, fluctuation ± 10%, 190VA
Analyzing alcoholic beverages by button operation alcoholic meter package drink analyzer PBA-Part Number-PBA 5001 Beer

PBA 5001 Beer

Available upon quote USB x 5, Ethernet, CAN, RS232 U-View ™, FillingCheck ™, ThermoBalance ™, full-range viscosity correction, Ultrafast measurement mode Measurement values ​​of 10,000 or more with camera image 0 ~ 120EBC 35 ° C: 0 ~ 5.5Vol. 0 ~ 4ppm 0 ~ 12%v/v 0 ~ 3g/cm³ 5 ~ 6.5bar (absolute pressure) 0 ~ 30 ° Plato PH 0 ~ 14 15 ℃ / 20 ℃ 0 ~ 10EBC / 0 ~ 400NTU 3 minutes (including filling) 150 0.005vol. (0.01g/L) - 0.01 0.1 0.000005 ~ 0.000001g/cm³ (measuring device: DMA 4501 or DMA 5001) 0.03 0.02ebc / 0.08ntu PH 3 ~ 7: 0.02 0.015 ~ 0.01%W/W less than W (measured device: DMA 4501 or DMA 500) Less than 200 ppb: 2PPB 0.01 ~ 0.001 ° C (measured device: DMA 4501 or DMA 5001) 15 sample/h Touch screen, options (keyboard, mouse, barcode reader) 10.1 inch, TFT WXGA (1,280 x 800px), PCAP touch screen AC 100-240V, 50/60Hz, fluctuation ± 10%, 190VA
Analyzing alcoholic beverages by button operation alcoholic meter package drink analyzer PBA-Part Number-PBA 5001 BEER + TPO 5000

PBA 5001 BEER + TPO 5000

Available upon quote USB x 5, Ethernet, CAN, RS232 U-View ™, FillingCheck ™, ThermoBalance ™, full-range viscosity correction, Ultrafast measurement mode Measurement values ​​of 10,000 or more with camera image 0 ~ 120EBC 35 ° C: 0 ~ 5.5Vol. Do: 0 ~ 2ppm
HSO: 0 ~ 45hpa
0 ~ 12%v/v 0 ~ 3g/cm³ 5 ~ 6.5bar (absolute pressure) 0 ~ 30 ° Plato PH 0 ~ 14 15 ℃ / 20 ℃ 0 ~ 10EBC / 0 ~ 400NTU 8 minutes (including filling) 260 0.005vol. (0.01g/L) 6% of ± 8PPB or measured value 0.01 0.1 0.000005 ~ 0.000001g/cm³ (measuring device: DMA 4501 or DMA 5001) 0.03 0.02ebc / 0.08ntu PH 3 ~ 7: 0.02 0.015 ~ 0.01%W/W less than W (measured device: DMA 4501 or DMA 500) - 0.01 ~ 0.001 ° C (measured device: DMA 4501 or DMA 5001) 7 Sample/H Touch screen, options (keyboard, mouse, barcode reader) 10.1 inch, TFT WXGA (1,280 x 800px), PCAP touch screen AC 100-240V, 50/60Hz, fluctuation ± 10%, 190VA
Analyzing alcoholic beverages by button operation alcoholic meter package drink analyzer PBA-Part Number-PBA 5001 Wine

PBA 5001 Wine

Available upon quote USB x 5, Ethernet, CAN, RS232 U-View ™, FillingCheck ™, ThermoBalance ™, full-range viscosity correction, Ultrafast measurement mode Measurement values ​​of 10,000 or more with camera image - 35 ° C: 0 ~ 5.5Vol. 0 ~ 4ppm 0 ~ 20%V/V 0 ~ 3g/cm³ 5 ~ 6.5bar (absolute pressure) - PH 0 ~ 14 15 ℃ / 20 ℃ 0 ~ 10EBC / 0 ~ 400NTU 3 minutes (including filling) 150 0.005vol. (0.01g/L) - 0.01 0.1 0.000005 ~ 0.000001g/cm³ (measuring device: DMA 4501 or DMA 5001) - 0.02ebc / 0.08ntu PH 3 ~ 7: 0.02 0.015 ~ 0.01%W/W less than W (measured device: DMA 4501 or DMA 500) Less than 200 ppb: 2PPB 0.01 ~ 0.001 ° C (measured device: DMA 4501 or DMA 5001) 15 sample/h Touch screen, options (keyboard, mouse, barcode reader) 10.1 inch, TFT WXGA (1,280 x 800px), PCAP touch screen AC 100-240V, 50/60Hz, fluctuation ± 10%, 190VA

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Anton Paar GmbH


View more products of Anton Paar GmbH

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree