Earth leakage fire alarm LD-25-LD-25
Earth leakage fire alarm LD-25-Hikari Shoko Co., Ltd.

Earth leakage fire alarm LD-25
Hikari Shoko Co., Ltd.


About This Product

■Earth leakage fire alarm The Fire Service Act establishes standards for earth leakage fire alarms as one of the "firefighting equipment, etc.," and their functions are strictly defined by national standards. In order to guarantee that each product passes the standards, we confirm the quality through "type evaluation" conducted by the Japan Fire Protection Certification Association, and further confirm that mass-produced commercially available products have no defects in quality through "type conformity evaluation." All products that pass the test are affixed with the national certification mark, guaranteeing quality and performance. Electrical leakage fire alarms are regulated by Article 22 of the Fire Service Act Enforcement Order, which stipulates that they must be installed in fire prevention properties, and they are also required to maintain and manage their functions. ■Regulations ・Regardless of the structure of the building, even if it is a fireproof building, it must be installed on buildings with lath mortar walls, floors, and ceilings. ・For buildings made of lath mortar in Articles (1) to (6), (15) and (16) of the Fire Service Act Enforcement Ordinance Appended Table 1 and whose contracted current capacity exceeds 50A, fire prevention measures shall be taken depending on the area. It must be installed without any problem. - As a general rule, current transformers should be installed on outdoor electrical circuits. ・In places where flammable steam, dust, etc. are present, a shutoff device that is linked to an electric leakage fire alarm should be installed. There are detailed regulations such as model selection, installation location, installation work, set current value, installation completion test, maintenance inspection, installation notification/inspection report, expiration date, etc. ■Features - Electrical leakage fire alarm. ・Please use a zero-phase current transformer for earth leakage fire alarms.

  • Product

    Earth leakage fire alarm LD-25

Share this product


20+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

1 Models of Earth leakage fire alarm LD-25

Product Image Part Number Price (excluding tax) Contact capacity Voltage-free contact Dielectric strength Exterior Insulation resistance Mass Nominal operating current value Notification number Operating current value Operating temperature range Operation display Power consumption Always Power consumption during operation Rated power supply voltage Return method Sound equipment Type Warning line voltage
Earth leakage fire alarm LD-25-Part Number-LD-25

LD-25

Available upon quote 1a, AC100V 1A 1,500V AC for 1 minute between all conductive parts except the current transformer connection terminal and the outer box ABS resin 5MΩ or more between all conductive parts and the outer box using a 500V DC megger Approximately 0.5kg 0.2-0.8 (A) E051001A 40~105% of the nominal operating current value (connect our current transformer) -10℃~+40℃ Light emitting diode display (red) 2.5VA 3.5VA AC100V 50/60Hz, allowable voltage range 80~110% Automatic return method Built-in buzzer Exposed type 600V or less