Ground fault directional relay Ground compensation capacitor-GC-16CA
Ground fault directional relay Ground compensation capacitor-Hikari Shoko Co., Ltd.

Ground fault directional relay Ground compensation capacitor
Hikari Shoko Co., Ltd.


About This Product

If an isolation transformer is used at the power receiving end of a private consumer, a ground fault relay is installed to detect ground faults in the load circuit. If the ground capacitance on the power supply side is smaller than the zero-phase current transformer, the ground fault current will not reach the operating sensitivity of the ground fault relay, making ground fault detection difficult. In order to operate the ground fault relay reliably, it is necessary to connect a ground compensation capacitor to the power supply side of the zero-phase current transformer to create a return circuit for the ground fault current. In low-voltage distribution lines, an ungrounded power distribution system is sometimes adopted, but in this case, as with high-voltage distribution lines, the ground capacitance on the power supply side is insufficient compared to the zero-phase current transformer, making it difficult to detect leakage. Therefore, a grounding compensation capacitor is required in such cases. Furthermore, the low voltage grounding compensation capacitor is a harmonic countermeasure product. ■Features ・Used for high-voltage ungrounded circuits on the secondary side of isolation transformers. - If the ground capacitance on the power supply side is smaller than the zero-phase current transformer, the ground fault current will not reach the operating sensitivity of the ground fault relay, making it difficult to detect ground faults. In order to operate the ground fault relay reliably, it is necessary to connect a ground compensation capacitor to create a return circuit for the ground fault current.

  • Product

    Ground fault directional relay Ground compensation capacitor

Share this product


20+ people viewing

Last viewed: 10 minutes ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

1 Models of Ground fault directional relay Ground compensation capacitor

Product Image Part Number Price (excluding tax) Ambient temperature Capacity tolerance Commercial frequency withstand voltage Exterior color Installation location Insulation strength Mass Maximum allowable voltage Rated capacitance Rated frequency Rated voltage
Ground fault directional relay Ground compensation capacitor-Part Number-GC-16CA

GC-16CA

Available upon quote -20℃~+60℃ ±5% of rated value (Between terminals/between terminals and case)
AC10,000V for 1 minute
DC30,000V for 10 seconds
Munsell symbol 5Y 7/1 Indoor use 10/30kV Approximately 9kg 115% of rated voltage 0.4μF×3 50/60Hz AC3,300/√3V