Price (excluding tax)
■ Model: SVM 3001 ・ The largest temperature range in the market of -60 to+135 ° C can be used ・ Measure all samples from jet fuel to wax without replacing the capillary ・ Cooling the sample to -20 ° C without using an external cooling device ・ Compliant with standards such as SAE J300, ASTM D396, D975, D7,666, ISO 23,581, EN 16,896 ・ Automatic multi -parameter analysis is possible by combining with XSAMPLE sample changer and abbemat refractor
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Built -in memory
Dimensions (width x depth x height)
HID (Human interface device)
Maximum sample loopput
Measurement range temperature
Measurement range viscosity
Minimum amount of solvent / normal amount
Net weight (kg)
Optional upgrade
Patent
Peripheral conditions
Repeated accuracy and reproducibility of the viscosity * 1
Repeated accuracy of accuracy temperature
Reproduction of accuracy temperature
Sample minimum amount / normal amount
Test method
accessories
interface
power supply
automation
Measurement range density
Repeated accuracy and reproducibility of accuracy * 1
Accurate cloudy point/repetition of accuracy and reproducibility * 1
Part Number
105001Handling Company
Anton Paar GmbHItems marked with have different values depending on the model number.
Product Image | Price (excluding tax) | Built -in memory | Dimensions (width x depth x height) | HID (Human interface device) | Maximum sample loopput | Measurement range density | Measurement range temperature | Measurement range viscosity | Minimum amount of solvent / normal amount | Net weight (kg) | Optional upgrade | Patent | Peripheral conditions | Repeated accuracy and reproducibility of accuracy * 1 | Repeated accuracy and reproducibility of the viscosity * 1 | Repeated accuracy of accuracy temperature | Reproduction of accuracy temperature | Sample minimum amount / normal amount | Test method | accessories | automation | interface | power supply |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Available upon quote | 1,000 measurement results can be saved | SVM (13,411,996), FillingCheck (6,834,725), ABBEMAT (1,084,545) | 7 inch touch screen | 33 sample/h | 0 ~ 3g/cm³ | -60 ~+135 ℃ | 0.2 ~ 30,000mm²/s | 1.5ml / 6ml | 33 x 51 x 23.1cm | Module with Hateroy Specifications ABBEMAT 300/500, 350/550, 450/650 | AT516,058 (B1), US10,036,695 (B2), CN105 ,424,556, EP2,995,928 (B1), AT516,302 (B1), CN105,628,550 | 17.6 | 0.00005g/cm³, 0.0001g/cm³ | 0.1%, 0.35% | 0.005 | +15 ~+100 ℃: 0.03 ℃ | 1.5ml / 5ml | ASTM D7,042, D445 bias correction, ISO 23,581, en 16,896, ASTM D4,052, ISO 12,185 | 7 inch touch screen | Optional sample changer +high -loopput platform HTV | USB x 4 (2.0 full speed), Ethernet x 1 (100 Mbit), CAN bus x 1, RS-232 x 1, VGA x 1 | 15 ~ 35 ° C, relative humidity of 80%or less, no condensation |