Price (excluding tax)
■ Model: SVM 2001 ・ The viscosity measurement of all samples is possible without replacing the capital ・ Measure motion at an arbitrary temperature of 15 to 100 ° C ・ Compliant with standards such as ASTM D396, D975, D3,699, D6,158, D6,823, D7,467 ・ Measure the viscosity index and density compliant with ASTM D4,052 ・ Automatic sample changer can be selected from a wide lineup
You can search for other models from each index. The displayed value is the value of the currently selected part number.
Built -in memory
Dimensions (width x depth x height)
HID (Human interface device)
Maximum sample loopput
Measurement range temperature
Measurement range viscosity
Minimum amount of solvent / normal amount
Net weight (kg)
Optional upgrade
Patent
Peripheral conditions
Repeated accuracy and reproducibility of the viscosity * 1
Repeated accuracy of accuracy temperature
Reproduction of accuracy temperature
Sample minimum amount / normal amount
Test method
accessories
interface
power supply
automation
Measurement range density
Repeated accuracy and reproducibility of accuracy * 1
Accurate cloudy point/repetition of accuracy and reproducibility * 1
Part Number
105000Handling Company
Anton Paar GmbHItems marked with have different values depending on the model number.
Product Image | Price (excluding tax) | Dimensions (width x depth x height) | Maximum sample loopput | Measurement range density | Measurement range temperature | Measurement range viscosity | Minimum amount of solvent / normal amount | Net weight (kg) | Optional upgrade | Patent | Peripheral conditions | Repeated accuracy and reproducibility of accuracy * 1 | Repeated accuracy and reproducibility of the viscosity * 1 | Repeated accuracy of accuracy temperature | Reproduction of accuracy temperature | Sample minimum amount / normal amount | Test method | automation | power supply |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Available upon quote | SVM (13,411,996), FillingCheck (6,834,725), ABBEMAT (1,084,545) | 33 sample/h | 0 ~ 3g/cm³ | +15 ~+100 ℃ | 0.2 ~ 30,000mm²/s | 1.5ml / 6ml | 33 x 51 x 23.1cm | Automatic VI Judgment ASTM D4,052 Measurement of density of compliant | AT516,058 (B1), US10,036,695 (B2), CN105 ,424,556, EP2,995,928 (B1) | 15.9 | 0.0002g/cm³ (0.00005g/cm² for the ASTM D4042 option), 0.0005g/cm³ (0.0001g/cm² for ASTM D4042 options) | 0.1%, 0.35% | 0.005 | +15 ~+100 ℃: 0.03 ℃ | 1.5ml / 5ml | ASTM D7,042, D445 bias correction, ISO 23,581, en 16,896 ASTM D4,052 (optional) | Optional sample changer +high -loopput platform HTV | 15 ~ 35 ° C, relative humidity of 80%or less, no condensation |