Inverter power supply for plating/anodizing MRT-BHandling Company
SANSHA ELECTRIC MANUFACTURING CO., LTD.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Current pulsation rate | Constant current control accuracy | Constant voltage control accuracy | Ratings/cooling method | Control method | Output range | Output | Input voltage | Input capacity | Conditions of use Installation location | Conditions of use Relative humidity | Conditions of use Altitude | Operating conditions Ambient temperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MRT-10005B |
Available upon quote |
RMS 5% or less (relative to rated value at rated input/output) |
Within ±3% of rated DC current |
Within ±3% of rated DC voltage |
Continuous/forced air cooling |
IGBT PWM inverter method |
10% to 100% of the rated value for both voltage and current |
10V-500A |
Three-phase AC200/220V ±10% or AC380/400/440V ±10% 50/60H |
6.5kVA |
Indoor |
30% ~ 85% |
Less than 1,000m |
0℃~40℃ |
|
MRT-15005B |
Available upon quote |
RMS 5% or less (relative to rated value at rated input/output) |
Within ±3% of rated DC current |
Within ±3% of rated DC voltage |
Continuous/forced air cooling |
IGBT PWM inverter method |
10% to 100% of the rated value for both voltage and current |
15V-500A |
Three-phase AC200/220V ±10% or AC380/400/440V ±10% 50/60H |
11.1kVA |
Indoor |
30% ~ 85% |
Less than 1,000m |
0℃~40℃ |
|
MRT-10010B |
Available upon quote |
RMS 5% or less (relative to rated value at rated input/output) |
Within ±3% of rated DC current |
Within ±3% of rated DC voltage |
Continuous/forced air cooling |
IGBT PWM inverter method |
10% to 100% of the rated value for both voltage and current |
10V-1,000A |
Three-phase AC200/220V ±10% or AC380/400/440V ±10% 50/60H |
13kVA |
Indoor |
30% ~ 85% |
Less than 1,000m |
0℃~40℃ |
|
MRT-15010B |
Available upon quote |
RMS 5% or less (relative to rated value at rated input/output) |
Within ±3% of rated DC current |
Within ±3% of rated DC voltage |
Continuous/forced air cooling |
IGBT PWM inverter method |
10% to 100% of the rated value for both voltage and current |
15V-1,000A |
Three-phase AC200/220V ±10% or AC380/400/440V ±10% 50/60H |
20.4kVA |
Indoor |
30% ~ 85% |
Less than 1,000m |
0℃~40℃ |
|
MRT-10015B |
Available upon quote |
RMS 5% or less (relative to rated value at rated input/output) |
Within ±3% of rated DC current |
Within ±3% of rated DC voltage |
Continuous/forced air cooling |
IGBT PWM inverter method |
10% to 100% of the rated value for both voltage and current |
10V-1,500A |
Three-phase AC200/220V ±10% or AC380/400/440V ±10% 50/60H |
20kVA |
Indoor |
30% ~ 85% |
Less than 1,000m |
0℃~40℃ |
|
MRT-15015B |
Available upon quote |
RMS 5% or less (relative to rated value at rated input/output) |
Within ±3% of rated DC current |
Within ±3% of rated DC voltage |
Continuous/forced air cooling |
IGBT PWM inverter method |
10% to 100% of the rated value for both voltage and current |
15V-1,500A |
Three-phase AC200/220V ±10% or AC380/400/440V ±10% 50/60H |
30.2kVA |
Indoor |
30% ~ 85% |
Less than 1,000m |
0℃~40℃ |
|
MRT-10020B |
Available upon quote |
RMS 5% or less (relative to rated value at rated input/output) |
Within ±3% of rated DC current |
Within ±3% of rated DC voltage |
Continuous/forced air cooling |
IGBT PWM inverter method |
10% to 100% of the rated value for both voltage and current |
10V-2,000A |
Three-phase AC200/220V ±10% or AC380/400/440V ±10% 50/60H |
26kVA |
Indoor |
30% ~ 85% |
Less than 1,000m |
0℃~40℃ |
|
MRT-15020B |
Available upon quote |
RMS 5% or less (relative to rated value at rated input/output) |
Within ±3% of rated DC current |
Within ±3% of rated DC voltage |
Continuous/forced air cooling |
IGBT PWM inverter method |
10% to 100% of the rated value for both voltage and current |
15V-2,000A |
Three-phase AC200/220V ±10% or AC380/400/440V ±10% 50/60H |
40.7kVA |
Indoor |
30% ~ 85% |
Less than 1,000m |
0℃~40℃ |
|
MRT-10030B |
Available upon quote |
RMS 5% or less (relative to rated value at rated input/output) |
Within ±3% of rated DC current |
Within ±3% of rated DC voltage |
Continuous/forced air cooling |
IGBT PWM inverter method |
10% to 100% of the rated value for both voltage and current |
10V-3,000A |
Three-phase AC200/220V ±10% or AC380/400/440V ±10% 50/60H |
39.5kVA |
Indoor |
30% ~ 85% |
Less than 1,000m |
0℃~40℃ |