Industrial Top Runner Molded Transformer TOP ECO II Series Three Phase (6kV/210V 20~1,500kVA)Handling Company
DAIHEN CorporationCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Load loss Wc (W) | Installation location | Heat resistance class | Total mass (kg) | Insulation strength Winding voltage 6kV class | Insulation strength Winding voltage 400V class | Insulation strength Winding voltage 200V class | Terminal shape secondary | Terminal shape Primary | Short circuit impedance (%) | Phase number | No-load loss Wi (W) | Temperature rise limit (K) | Elevation | Connection symbol | Target category | Capacity (kVA) | Rated current (A) Secondary | Rated current (A) Primary | Circuit voltage waveform | Frequency (Hz) | Ambient temperature | Secondary voltage (V) | Voltage balance in three-phase circuits | Primary voltage (V) | Energy consumption efficiency (W) standard value | Energy consumption efficiency (W) typical value |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
T2MP-20K-C |
Available upon quote |
196 |
Indoor use |
F |
260 |
AC test voltage: 22kV |
AC test voltage: 4kV |
AC test voltage: 2kV |
L11 |
H3 |
1.8 |
Three phase |
110 |
95 |
Less than 1,000m |
Yy0 |
JIS standard product |
20 |
55 |
1.75 |
The voltage waveform of the circuit to which the transformer is connected must be approximately a sine wave. |
50 |
-5~40℃ |
210 |
The voltages of the three-phase circuit to which the three-phase transformer is connected are approximately balanced. |
R6600 |
172 |
141 |
|
T2MP-30K-C |
Available upon quote |
442 |
Indoor use |
F |
260 |
AC test voltage: 22kV |
AC test voltage: 4kV |
AC test voltage: 2kV |
L11 |
H3 |
2.7 |
Three phase |
110 |
95 |
Less than 1,000m |
Yy0 |
JIS standard product |
30 |
82.5 |
2.62 |
The voltage waveform of the circuit to which the transformer is connected must be approximately a sine wave. |
50 |
-5~40℃ |
210 |
The voltages of the three-phase circuit to which the three-phase transformer is connected are approximately balanced. |
R6600 |
224 |
181 |
|
T2MP-50K-C |
Available upon quote |
1,230 |
Indoor use |
F |
260 |
AC test voltage: 22kV |
AC test voltage: 4kV |
AC test voltage: 2kV |
L11 |
H3 |
4.5 |
Three phase |
110 |
95 |
Less than 1,000m |
Yy0 |
JIS standard product |
50 |
137 |
4.37 |
The voltage waveform of the circuit to which the transformer is connected must be approximately a sine wave. |
50 |
-5~40℃ |
210 |
The voltages of the three-phase circuit to which the three-phase transformer is connected are approximately balanced. |
R6600 |
314 |
307 |
|
T2MP-75K-C |
Available upon quote |
1,140 |
Indoor use |
F |
400 |
AC test voltage: 22kV |
AC test voltage: 4kV |
AC test voltage: 2kV |
L11 |
H3 |
3.8 |
Three phase |
208 |
95 |
Less than 1,000m |
Yd1 |
JIS standard product |
75 |
206 |
6.56 |
The voltage waveform of the circuit to which the transformer is connected must be approximately a sine wave. |
50 |
-5~40℃ |
210 |
The voltages of the three-phase circuit to which the three-phase transformer is connected are approximately balanced. |
F6750 |
411 |
390 |
|
T2MP-100K-C |
Available upon quote |
1,740 |
Indoor use |
F |
410 |
AC test voltage: 22kV |
AC test voltage: 4kV |
AC test voltage: 2kV |
L11 |
H3 |
4.7 |
Three phase |
208 |
95 |
Less than 1,000m |
Yd1 |
JIS standard product |
100 |
275 |
8.75 |
The voltage waveform of the circuit to which the transformer is connected must be approximately a sine wave. |
50 |
-5~40℃ |
210 |
The voltages of the three-phase circuit to which the three-phase transformer is connected are approximately balanced. |
F6750 |
497 |
486 |
|
T2MP-150K-C |
Available upon quote |
1,630 |
Indoor use |
F |
620 |
AC test voltage: 22kV |
AC test voltage: 4kV |
AC test voltage: 2kV |
L5 |
H1 |
4.2 |
Three phase |
372 |
95 |
Less than 1,000m |
Yd1 |
JIS standard product |
150 |
412 |
13.1 |
The voltage waveform of the circuit to which the transformer is connected must be approximately a sine wave. |
50 |
-5~40℃ |
210 |
The voltages of the three-phase circuit to which the three-phase transformer is connected are approximately balanced. |
F6750 |
649 |
633 |
|
T2MP-200K-C |
Available upon quote |
2,480 |
Indoor use |
F |
785 |
AC test voltage: 22kV |
AC test voltage: 4kV |
AC test voltage: 2kV |
L5 |
H1 |
4.2 |
Three phase |
365 |
95 |
Less than 1,000m |
Yd1 |
JIS standard product |
200 |
550 |
17.5 |
The voltage waveform of the circuit to which the transformer is connected must be approximately a sine wave. |
50 |
-5~40℃ |
210 |
The voltages of the three-phase circuit to which the three-phase transformer is connected are approximately balanced. |
F6750 |
784 |
762 |
|
T2MP-300K-C |
Available upon quote |
2,790 |
Indoor use |
F |
1,030 |
AC test voltage: 22kV |
AC test voltage: 4kV |
AC test voltage: 2kV |
L5 |
H1 |
4.5 |
Three phase |
545 |
95 |
Less than 1,000m |
Yd1 |
JIS standard product |
300 |
825 |
26.2 |
The voltage waveform of the circuit to which the transformer is connected must be approximately a sine wave. |
50 |
-5~40℃ |
210 |
The voltages of the three-phase circuit to which the three-phase transformer is connected are approximately balanced. |
F6750 |
1,020 |
991 |
|
T2MP-500K-C |
Available upon quote |
3,920 |
Indoor use |
F |
1,520 |
AC test voltage: 22kV |
AC test voltage: 4kV |
AC test voltage: 2kV |
L6 |
H1 |
5 |
Three phase |
765 |
95 |
Less than 1,000m |
Yd1 |
JIS standard product |
500 |
1,375 |
43.7 |
The voltage waveform of the circuit to which the transformer is connected must be approximately a sine wave. |
50 |
-5~40℃ |
210 |
The voltages of the three-phase circuit to which the three-phase transformer is connected are approximately balanced. |
F6750 |
1,430 |
1,392 |
|
T2MP-750K-C |
Available upon quote |
5,410 |
Indoor use |
F |
1,870 |
AC test voltage: 22kV |
AC test voltage: 4kV |
AC test voltage: 2kV |
L7 |
H1 |
5.7 |
Three phase |
1,190 |
95 |
Less than 1,000m |
Dd0 |
JIS standard product |
750 |
2,062 |
65.6 |
The voltage waveform of the circuit to which the transformer is connected must be approximately a sine wave. |
50 |
-5~40℃ |
210 |
The voltages of the three-phase circuit to which the three-phase transformer is connected are approximately balanced. |
F6750 |
2,630 |
2,543 |
Click on the part number for more information about each product