All Categories

History

100 -cycle continuous operation and stainless steel exterior design Cosmopia Gardeni Heat Shock Test Series Standard Series-ES-57L
100 -cycle continuous operation and stainless steel exterior design Cosmopia Gardeni Heat Shock Test Series Standard Series-Satake Martimics Co., Ltd.

100 -cycle continuous operation and stainless steel exterior design Cosmopia Gardeni Heat Shock Test Series Standard Series
Satake Martimics Co., Ltd.

Satake Martimics Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

14.3hours

Relatively Fast Response


About This Product

■ New function: USB memory storage function

You can save trend graph data to USB memory. This is a function to save the data (measured temperature) displayed in the trend graph of the liquid crystal operation panel in a USB memory format format.

■ New function: Data log function

It is a function to save cycle data during operation in USB memory (cycle data). If an alarm is stopped due to an abnormal detection, it is a function to save the operation status of the device just before the stop in a USB memory. By recovering the data just before the stop, failure analysis is possible (backtress).

■ Caster / Level Assaster

Equipped with casters / level adjuster for equipment movement.

■ 100 cycle continuous operation

2 Zone (low temperature test ⇔ high temperature test) can be operated without defrosting up to 100 cycles.

■ Exterior design is new

Stainless steel (hairline finish) is used for the exterior material, and a clear cover is attached to the left and right of the device to renew the design.

■ Signal external output terminal

Time signal, sample power supply, external warning output terminal standard equipment.

■ Communication interface

RS-232C interface function is standard equipment. (Connected cable is optional)

■ Equipped with a color LCD touch panel that is easy to see, good operability

All settings and switch operations are integrated into the liquid crystal panel.

■ Language switching function

The language displayed in the liquid crystal operation panel can be changed on the operation panel. The corresponding language is four languages: Japanese, English, Chinese (simplified), and Korean.

■ Pattern combination

You can test up to three test patterns.

■ Timer reservation

It is possible to operate and stop with a timer reservation. You can set the exam reservation according to the usage status, such as the end time of the exam, within business hours or the next test timing.

■ Notes function

It is a function that can use the liquid crystal operation panel as a notepad. You can write letters, lines, pictures, etc. directly on the LCD operation panel with a pen used for your finger or an electronic notebook. Up to 8 can be registered.

■ Trend graph screen

Displays the trend graph of the measured temperature of the test tank. You can scroll and reset the display.

  • Product

    100 -cycle continuous operation and stainless steel exterior design Cosmopia Gardeni Heat Shock Test Series Standard Series

Share this product


370+ people viewing

Last viewed: 2 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

2 Models of 100 -cycle continuous operation and stainless steel exterior design Cosmopia Gardeni Heat Shock Test Series Standard Series

Click on the part number for more information about each product

Image Part Number Price (excluding tax) method Temperature range (test tank) low temperature test (℃) Temperature range (test tank) High temperature test (℃) Temperature fluctuation width (℃) Temperature rising time (high temperature tank) Temperature drop time (low temperature tank) Temperature cycle performance cycle Temperature cycle performance sample type Temperature cycle performance sample mass Temperature cycle performance test tank temperature / test time (low temperature) Temperature cycle performance test tank temperature / test time (room temperature) Temperature cycle performance test tank temperature / test time (high temperature) Temperature cycle performance temperature measurement position Temperature cycle performance return time cooling method Exterior Test tank volume (L) Examination tank dimension width (mm) Examination tank dimension depth (mm) Examination tank dimension height (mm) Product dimension width (mm) Product dimension depth (mm) Product dimension height (mm) Telegrated in the test tank (kg) Type of refrigerant high temperature side Type of refrigerant low temperature side Driving sound DB (a) Protective device accessories Dry air pressure (MPA) Dry air consumption l (anR) power supply Maximum load current / power supply capacity (A / KVA) Product mass (kg)
100 -cycle continuous operation and stainless steel exterior design Cosmopia Gardeni Heat Shock Test Series Standard Series-Part Number-ES-57L

ES-57L

Available upon quote

Still, cold / warm air switching method, 2 zones / 3 zones can be switched

-70 ~ 0

60-200

± 0.5

Room temperature → 200 ° C: within 15 minutes (surrounding temperature 20 ° C)

Room temperature → -75 ° C: within 75 minutes (surrounding temperature: 20 ° C)

5 cycle (low temperature start)

Plastic mold IC

3.5kg (IC2.5kg+jig 1.0kg)

-55 ℃ / 30 minutes

Atmosphere temperature / 5 minutes

150 ° C / 30 minutes

Wind side

Within 5 minutes (surrounding temperature: 10 to 30 ° C)

Air -cooled type (built -in body)

Stainless steel plate (SUS430 hairline finish)

47

275

375

460

1,140

1,050

1,980

30

R404A

R508A

65

Electrical leakage breakers, electric fuse protection devices, electric fuses, high -pressure blocking devices for freezer, door open operation prevention switch, temperature hoody prevention device, temperature fuse

Soft silicone plug for cable holes, 1 piece of sample shelf, 2 shelves, 4 shelves, operating circuit protection fuse x 2 pieces, instruction manual x 1 part

0.4 ~ 0.7

About 7.6 per cycle

Three -phase 200V 50/60Hz

43/15

550

100 -cycle continuous operation and stainless steel exterior design Cosmopia Gardeni Heat Shock Test Series Standard Series-Part Number-ES-107L

ES-107L

Available upon quote

Still, cold / warm air switching method, 2 zones / 3 zones can be switched

-70 ~ 0

60-200

± 0.5

Room temperature → 200 ° C: within 15 minutes (surrounding temperature 20 ° C)

Room temperature → -75 ° C: within 70 minutes (surrounding temperature: 20 ° C)

5 cycle (low temperature start)

Plastic mold IC

5kg (IC3.5kg+jig 1.5kg)

-55 ℃ / 30 minutes

Atmosphere temperature / 5 minutes

150 ° C / 30 minutes

Wind side

Within 5 minutes (surrounding temperature: 10 to 30 ° C)

Air -cooled type (built -in body)

Stainless steel plate (SUS430 hairline finish)

105

470

485

460

1,380

1,270

1,980

50

R404A

R23

65

Electrical leakage breakers, electric fuse protection devices, electric fuses, high -pressure blocking devices for freezer, door open operation prevention switch, temperature hoody prevention device, temperature fuse

Soft silicone plug for cable holes, 1 piece of sample shelf, 2 shelves, 4 shelves, operating circuit protection fuse x 2 pieces, instruction manual x 1 part

0.4 ~ 0.7

About 7.6 per cycle

Three -phase 200V 50/60Hz

60/21

800

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Environmental Testers Products

Other products of Satake Martimics Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Satake Martimics Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

14.3hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree