Chemical Industry Use / Food Industry Use / Environment & Recycling UseImage | Part Number | Price (excluding tax) | Measurement ingredient | Measurement principle | Measurement method | Effective measurement range | display | Reproducibility | Water inspection PH range | Radius | Transmission output | memory card | Contact output | Contact capacity | power supply | power consumption | Peripheral temperature range | Installation method |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GR-10 (GR-10L-200A-253C) |
Available upon quote |
Play residual chlorine |
Polaralograph method |
Bead cleaning type microscope 3 electrode system |
0.00 ~ 1.00 mg/L (standard) |
Measurement value display part (PV): Digital 4 -digit LED display minimal resolution: 0.01 mg/l |
Within ± 5%+1 digit of full scale (PH, temperature, constant power conduction) |
PH5.8 ~ 8.2 (within 0.5PH) |
5ms/m or higher |
DC4 ~ 20ma Insulated maximum load resistance 550Ω |
SDHC/SD card log data storage (standard size SD slot) |
Control output, upper limit, lower limit: 1A device abnormality: 1b |
Control output relay: AC peak 400V 0.5A max. |
1φac100V ~ 240V 50/60Hz |
Approximately 20VA |
-10 ~ 45 ℃ |
Mounting wall or 50A pipe installation |